The optimal incubation time for in vitro hemocompatibility testing: Assessment using polymer reference materials
Sjoerd Leendert Johannes Blok1, Willem van Oeveren1,2, Gerwin Erik Engels1,2
1HaemoScan BV, 9723 JC, Groningen, The Netherlands.
Abstract:
During hemocompatibility testing, activation products may reach plateau values which can result in less distinction between hemocompatible and hemo-incompatible materials. Of concern is an underestimation of the blood activation caused by the biomaterial of interest, which may result in a false assessment of hemocompatibility. To elucidate the optimal incubation time for in vitro hemocompatibility testing, we used the Haemobile circulation model with human whole blood. Blood from healthy volunteers was in vitro incubated under pulsatile flow with physiological wall shear stress conditions at 37°C for 30, 60, 120, or 240 min. Test loops containing low-density polyethylene and polydimethylsiloxane served as low and high reference materials, that is, hemocompatible and hemo-incompatible biomaterials, respectively. In addition, empty loops served as a negative reference. Thrombogenicity, platelet function, inflammatory response, coagulation, and hemolysis between references and incubation times were compared. We found that thrombogenicity and platelet function were significantly affected by both the duration of incubation and the type of material. In particular, thrombogenicity and platelet function assessments were affected by incubation time. We found that an exposure time of 60 min was sufficient, and for almost all variables an optimal incubation time to discriminate between the low and high reference material. © 2019 The Authors. Journal of Biomedical Materials Research Part B: Applied Biomaterials published by Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B: 2335-2342, 2019.
More Related Videos
09:41Hemocompatibility Testing of Blood-Contacting Implants in a Flow Loop Model Mimicking Human Blood Flow
Published on: March 5, 2020
09:20The Assembly and Application of 'Shear Rings': A Novel Endothelial Model for Orbital, Unidirectional and Periodic Fluid Flow and Shear Stress
Published on: October 31, 2016
Related Concept Videos
Shearing Stress
The average shearing stress can be calculated by dividing the shear by the area of the cross-section.
Shearing Stresses in a Beam: Problem Solving
Physiological Foundation of Stress
Role of the Sympathetic Nervous System
Adrenaline triggers the...
Stress: General Loading Conditions
The shearing force, possessing potential directionality within the plane of the section, is simplified into two component forces running parallel to the x and y axes....
Elastic Strain Energy for Shearing Stresses
Polymers