Feasibility and tolerability of measuring translaryngeal pressure during exercise
Zoe Fretheim-Kelly1,2, Thomas Halvorsen2,3, John-Helge Heimdal4
1Faculty of Veterinary Science, Norwegian University of Life Sciences, Oslo, Norway.
Objectives/Hypothesis:
To determine if simultaneous tracheal and supraglottic pressure measurement performed during a continuous laryngoscopy exercise (CLE) test is possible, tolerable, and feasible, and if so, whether measurements can be used to determined airflow resistance over the larynx, thus providing an objective outcome measure for the CLE test, the gold standard for diagnosing exercise-induced laryngeal obstruction.
Study Design:
Explorative descriptive clinical study.
Methods:
A CLE test was performed with the addition of two pressure sensors (Mikro-Cath 825-0101; Millar, Houston, TX) placed at the epiglottic tip and at the fifth tracheal ring. To place sensors, laryngeal anesthesia and a channel scope were required. Tolerability and feasibility was determined by a Likert score and subjective indication from subjects and operators. Adjustments to the technique were made to increase tolerability. The pressure data were continuously collected and analyzed for artifacts, drifts, frequency response, and used with flow data to calculate translaryngeal resistance.
Results:
All subjects (n = 7) completed all procedures. Two main areas of concern were identified regarding tolerability: application of topical anesthesia to the larynx and nasal discomfort due to the added diameter of the laryngoscope. Protocol adjustments improved both. Pressure data were obtained from all procedures in all subjects, were consistent, and followed physiological trends.
Conclusions:
Continuous measurement of the translaryngeal pressure gradient during a CLE test is possible, feasible, and tolerable. A CLE test with direct measurement of the translaryngeal pressure gradient might become a valuable tool in the objective assessment of respiratory function, and normal values should be established in health and disease.
Level Of Evidence:
NA Laryngoscope, 129:2748-2753, 2019.
More Related Videos
04:53Measuring Exercise Levels in Drosophila melanogaster Using the Rotating Exercise Quantification System REQS
Published on: May 27, 2018
07:26Conducting Maximal and Submaximal Endurance Exercise Testing to Measure Physiological and Biological Responses to Acute Exercise in Humans
Published on: October 17, 2018
Related Concept Videos
Definition and Measurement of Pressure: Atmospheric Pressure, Barometer, and Manometer
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes