Related Experiment Video
Updated: Jan 30, 2026

Thermal Measurement Techniques in Analytical Microfluidic Devices
Published on: June 3, 2015
Equipment-Free Detection of K+ on Microfluidic Paper-Based Analytical Devices Based on Exhaustive Replacement with
Yoshiki Soda1, Daniel Citterio2, Eric Bakker1
1Department of Inorganic, Analytical Chemistry , University of Geneva , Quai Ernest-Ansermet 30 , CH-1211 Geneva , Switzerland.
Abstract:
A distance-based analysis of potassium ion (K+) is introduced that is performed on a microfluidic paper-based analytical device (μPAD) coupled to an ion-selective capillary sensor. The concept is based on two sequential steps, the selective replacement of analyte ion with an ionic dye, and the detection of this dye in a distance-based readout on paper. To achieve the first step, the capillary sensor holds a poly(vinyl chloride) (PVC) membrane film layer plasticized by dioctyl sebacate (DOS) that contains the potassium ionophore valinomycin, a lipophilic cation-exchanger and the ionic indicator Thioflavin T (ThT) on its inner wall. Upon introduction of the sample, K+ in the aqueous sample solution is quantitatively extracted into the film membrane and replaced with ThT. To convert the ion exchange signal into a distance-based analysis, this solution was dropped onto the inlet area of a μPAD to flow the ThT along a channel defined by wax printing, resulting in the electrostatic binding of ThT to the cellulose carboxylic groups. The initial amount of K+ determines the amount of ThT in the aqueous solution after ion-exchange, and consequently the distance of ThT-colored area reflects the sample K+ concentration. The ion exchange reaction was operated in a so-called "exhaustive sensing mode" and gave a distinct response in a narrow range of K+ concentration (1-6 mM) that cannot be achieved by the classical optode sensing mode. The absence of hydrogen ions from the equilibrium competition of the capillary sensor contributed to a complete pH-independence, unlike conventional optodes that contain a pH sensitive indicator. A very high selectivity for K+ over Na+ and Ca2+ has been confirmed in separate solutions and mixed solutions tests. K+ measurements in pooled serum samples at concentrations between 2 and 6 mM are successfully demonstrated on a temperature controlled support.
Related Concept Videos
Ions as Acids and Bases
Salts are ionic compounds composed of cations and anions, either of which may be capable of undergoing an acid or base ionization reaction with water. Aqueous salt solutions, therefore, may be acidic, basic, or neutral, depending on the relative acid-base strengths of the salt’s constituent ions. For example, dissolving the ammonium chloride in water results in its dissociation, as described by the equation:
Ions and Ionic Charges
Ionic Radii
Ionic Bonds
When atoms gain or lose electrons to achieve a more stable electron configuration they form ions. Ionic bonds are electrostatic attractions between ions with opposite charges. Ionic compounds are rigid and brittle when solid and may dissociate into their constituent ions in water. Covalent compounds, by contrast, remain intact unless a chemical reaction breaks them.
Opposing Charges Hold Ions Together in Ionic Compounds
Ionic bonds are reversible electrostatic interactions between ions...
Ionic Compounds: Formulas and Nomenclature
Strong Acid and Base Solutions

