Related Experiment Video
Updated: Jan 30, 2026

Loop-mediated Isothermal Amplification LAMP Assays for the Species-specific Detection of Eimeria that Infect Chickens
Published on: February 20, 2015
Improving the Detection Accuracy and Time for Campylobacter jejuni and Campylobacter coli in Naturally Infected Live
Islam Ibrahim Sabike1,2, Wataru Yamazaki1,3
11 Department of Veterinary Sciences, Faculty of Agriculture (ORCID: http://orcid.org/0000-0002-7874-8014 [W.Y.]), University of Miyazaki, Miyazaki, Japan.
Abstract:
Rapid and accurate identification of Campylobacter-positive broiler flocks and carcasses expedites separation and control interventions before release into the food supply chain and directly facilitates a reduction in the prevalence of human campylobacteriosis. In this study, the diagnostic performance of fluorescent loop-mediated isothermal amplification (LAMP) assays for the direct detection of Campylobacter jejuni and Campylobacter coli in broiler cloacal and cecal samples were evaluated and compared with that of turbidimetric LAMP approaches investigated previously. The duplex fluorescent LAMP assay had significantly higher ( P < 0.05) diagnostic sensitivity (93.1%, 54 of 58 samples) than did the turbidimetric LAMP assay (82.8%, 48 of 58 samples) for detecting C. jejuni and C. coli in broiler cloacal samples, whereas the singleplex fluorescent LAMP assay had equivalent diagnostic sensitivity. For cecal samples, the diagnostic sensitivity of the fluorescent LAMP assay (100%, 38 of 38 samples) was the same as that of the turbidimetric LAMP. Fluorescent LAMP significantly reduced ( P < 0.05) the maximum detection time for Campylobacter-positive cloacal and cecal samples to 28 and 11 min, respectively, and reduced the influence of amplification inhibitors responsible for most false-negative results obtained for cloacal samples with the turbidimetric LAMP assay. The diagnostic accuracy of the fluorescent LAMP assay for the direct detection of C. jejuni and C. coli in cloacal and cecal samples was 97.7 and 100%, respectively. These findings indicate that fluorescent LAMP assays are robust, highly accurate, and field-applicable methods for the identification of C. jejuni and C. coli, which will allow more accurate monitoring of food safety at various stages of the food supply chain at farms and slaughter facilities.
More Related Videos
05:34Author Spotlight: Development of an Enhanced Protocol for Rapid and Accurate Isolation of Campylobacter from Food Products
Published on: February 23, 2024
08:23Culture Methods to Determine the Limit of Detection and Survival in Transport Media of Campylobacter Jejuni in Human Fecal Specimens
Published on: March 10, 2020
Related Concept Videos
Improving Translational Accuracy
Improving Translational Accuracy
Real Time RT-PCR
The real-time quantification of the number of amplified products is...
Mean free path and Mean free time
Mixing Time
Generation Time