Related Experiment Video
Updated: Jan 30, 2026

A Simple Pit Assay Protocol to Visualize and Quantify Osteoclastic Resorption In Vitro
Published on: June 16, 2022
Low accuracy of microscopic hematuria in detecting coagulopathy from Bothrops pit viper bites, Brazilian Amazon
Jose Diego de Brito Sousa1,2, Sâmella Silva de Oliveira1,2, Jacqueline Sachett1,2,3
1a Instituto de Pesquisa Clínica Carlos Borborema, Fundacão de Medicina Tropical Dr. Heitor Vieira Dourado , Manaus , Brazil.
Abstract:
Introduction: The common lancehead snakes (Bothrops atrox) are responsible for up to 90% of snakebites in the Amazon, especially in remote areas. The prevalence of microhematuria is similar to that of coagulopathy in B. atrox envenomation in the Amazon. Thus, this study aimed to assess the reliability of microhematuria as an inexpensive and simple alternative to detect snake-induced consumption coagulopathy. Methods: We analyzed samples from patients with confirmed B. atrox envenomation in terms of plasma fibrinogen and microhematuria (>3 red blood cells per high power field) in order to access the reliability of microhematuria to detect snakebite-induced coagulopathy, within 12 hours from admission. Results: A total of 186 patients were recruited. From the total, 85.5% of patients had hypofibrinogenemia and only about 50% (n = 94) had a microscopic examination of urine within 12 hours where microhematuria was present in 39 (41.5%). Diagnostic performance showed 38.6% sensitivity and 36.4% specificity (cutpoint 200 mg/dL). No clear association was seen between microhematuria and hypofibrinogenemia (r: -0.10; p: .34). Conclusion: In this study, microhematuria presented poor diagnostic performance to detect coagulopathy. Further studies are necessary to screen inexpensive and simple alternative diagnostic tools.
Related Concept Videos
Improving Translational Accuracy
Improving Translational Accuracy
Uncertainty in Measurement: Accuracy and Precision
Accuracy and Precision
Accuracy, limits, and approximation
Accuracy is defined as the closeness of the measured value to the true or actual value. In engineering mechanics, repeated measurements are taken during theoretical or experimental analyses to ensure that the result is precise and accurate.
The accuracy of any solution is based on the...
Accuracy and Errors in Hypothesis Testing
In hypothesis testing, the probability of making a Type I error, denoted as α, is commonly set at 0.05. This significance level indicates a 5%...

