Related Experiment Video
Updated: Jan 30, 2026

Ethylene Polymerizations Using Parallel Pressure Reactors and a Kinetic Analysis of Chain Transfer Polymerization
Published on: November 27, 2015
Analysis of patellofemoral arthrokinematic motion quality in open and closed kinetic chains using vibroarthrography
Dawid Bączkowicz1, Krzysztof Kręcisz2, Zbigniew Borysiuk2
1Institute of Physiotherapy, Faculty of Physical Education and Physiotherapy, Opole University of Technology, Prószkowska 76, PL-45-578, Opole, Poland. d.baczkowicz@po.opole.pl.
Background:
Knee movements performed in open (OKC) and closed (CKC) kinetic chains generate various patterns of muscle activities and especially distinct contact stresses in the patellofemoral joint (PFJ). In contrast to these features, the arthrokinematic motion quality (AMQ) of the PFJ has not been compared between mentioned conditions. In this study we performed vibroarthrographic analysis of AMQ in movements performed in OKC and CKC, in healthy subjects and individuals with chondromalacia patellae, to assess which of the test conditions is more efficient in differentiation between healthy and deteriorated joints. Moreover, our analysis will broaden the knowledge related to behavior of normal and pathological synovial joints during motion with and without weight bearing. It is an essential issue, due to the recently observed significant interest in comparing potential benefits and limitations of CKC and OKC exercises as they relate to lower extremity rehabilitation.
Methods:
100 subjects (62 healthy controls and 38 subjects with PFJ chondromalacia) were enrolled. During repeated knee flexion/extension motions performed in OKC (in a sitting position) and CKC (sit-to-stand movements), the vibroarthrographic signals were collected using an accelerometer and described by variability (VMS), amplitude (R4), and spectral power in 50-250 Hz (P1) and 250-450 Hz (P2) bands.
Results:
Significant differences in VMS [V], R4 [V], P1 [V2/Hz] and P2 [V2/Hz] between OKC and CKC were found (0.0001, 0.969. 0.800 0.041 vs 0.013, 3.973, 6.790, 0.768, respectively, P < 0.001). Moreover, in both analyzed load-related conditions the subjects with chondromalacia were characterized by significantly higher values of all parameters, when compared to controls (P < 0.001), with effect size values over 0.6.
Conclusions:
We showed that motion of the physiological, unloaded PFJ articular surfaces in OKC is nearly vibrationless, which corresponds with optimal AMQ of PFJ, while loaded movements in CKC are characterized by a higher vibroacoustic emission level. Moreover, chondral lesions should be considered as an increased friction-related, aggravating factor of AMQ, which is critical in CKC movements under load. Nonetheless, OKC and CKC conditions are characterized by large effect sizes, and provide an efficient test frame for differentiating physiological knees and joints with chondral lesions.
More Related Videos
Related Concept Videos
Kinetic Energy
Absolute Motion Analysis- General Plane Motion
As the drone's propellers rotate, an upward force is generated that counteracts the force of gravity, enabling the drone to lift off from the ground. This initial movement of the drone is along a straight path, representing a form of translational motion. In this phase, every point on the...
Relative Motion Analysis - Velocity
When an external force is exerted, it sets the crank into a rotational movement. This, in turn, instigates the motion of the connecting rod, leading to what is referred to as a general plane motion. This process involves two key points - point A on the connecting rod...
Relative Motion Analysis - Acceleration
Enzyme Kinetics
Scientists typically study enzyme kinetics with a fixed amount of enzyme in the controlled environment of a test tube. When more reactant, or substrate, is...
Kinetic Molecular Theory: Molecular Velocities, Temperature, and Kinetic Energy

