Tertiary stent-in-stent for obstructing colorectal cancer: A case report and literature review
Giuseppe Vanella1, Chiara Coluccio1, Emilio Di Giulio2
1Department of Digestive Endoscopy, Sant'Andrea Hospital, Sapienza University of Rome, Rome 00189, Italy.
Background:
Self-expandable metal stents (SEMSs) are frequently used in the setting of palliation for occluding, inoperable colorectal cancer (CRC). Among possible complications of SEMS positioning, re-obstruction is the most frequent. Its management is controversial, potentially involving secondary stent-in-stent placement, which has been poorly investigated. Moreover, the issue of secondary stent-in-stent re-obstruction and of more-than-two colonic stenting has never been assessed. We describe a case of tertiary SEMS-in-SEMS placement, and also discuss our practice based on available literature.
Case Summary:
A 66-year-old male with occluding and metastatic CRC was initially treated by positioning of a SEMS, which had to be revised 6 mo later when a symptomatic intra-stent tumor ingrowth was treated by a SEMS-in-SEMS. We hereby describe an additional episode of intestinal occlusion due to recurrence of intra-stent tumor ingrowth. This patient, despite several negative prognostic factors (splenic flexure location of the tumor, carcinomatosis with ascites, subsequent chemotherapy that included bevacizumab and two previously positioned stents (1 SEMS and 1 SEMS-in-SEMS)) underwent successful management through the placement of a tertiary SEMS-in-SEMS, with immediate clinical benefit and no procedure-related adverse events after 150 d of post-procedural follow-up. This endoscopic management has permitted 27 mo of partial control of a metastatic disease without the need for chemotherapy discontinuation and, ultimately, a good quality of life until death.
Conclusion:
Tertiary SEMS-in-SEMS is technically feasible, and appears to be a safe and effective option in the case of recurrent SEMS obstruction.
Related Concept Videos
Tertiary Healthcare System
Review and Preview
Percentiles are a type of fractile that partition data into...
Review and Preview
Nomenclature of Secondary and Tertiary Amines
Data Reporting and Recording
Types of Reports I: Hands-off Report
Following are the key components and categories of hand-off reports:
Purpose and Process: