Related Experiment Video
Updated: Jan 30, 2026

Dynamic Lung Tumor Tracking for Stereotactic Ablative Body Radiation Therapy
Published on: June 7, 2015
Analysis of MRI Volumetric Changes After Hypofractionated Stereotactic Radiation Therapy for Benign Intracranial
Kathryn R Fega1, Geoffrey P Fletcher2, Mark R Waddle3
1Department of Radiation Oncology, Mayo Clinic Hospital, Phoenix, Arizona.
Purpose:
To quantitatively assess volumetric changes after hypofractionated stereotactic radiation therapy (HFSRT) in patients treated for vestibular schwannomas and meningiomas.
Methods And Materials:
We retrospectively reviewed records of patients treated with HFSRT at our institution from 2002 to 2014. Patients received a median dose of 25 Gy in 5 fractions. After treatment, they underwent clinical and radiologic follow-up with magnetic resonance imaging (MRI) at 3- to 12-month intervals. Gross tumor volume was outlined on each thin slice of contrast-enhanced T1 series before and on each scan after HFSRT. Volumetric changes were calculated and compared with neuroradiologist interpretations.
Results:
Forty-three patients underwent 182 MRI scans. Tumor types included vestibular schwannoma (n = 34) and meningioma (n = 9). Median follow-up time was 29 months. Median gross tumor volume was 3.1 cm3. Local control was 81.4% for the entire cohort at the time of last follow-up. Transient volume expansion was noted in 17 patients (50%) with vestibular schwannoma and 2 (22%) with meningioma. For all patients, transient volume expansion and subsequent regression occurred at a median time of 5.5 and 12 months, respectively. Neuroradiologist agreement with regard to tumor regression, progression, or stability occurred in 155 of 182 total reports (85%). The largest discordance identified was a stable finding on the MRI interpretation when the measured volumetric change exceeded 20% (n = 24 [13%]).
Conclusions:
HFSRT is associated with excellent local control and a low incidence of toxicity. With volumetric MRI measurement, transient volume expansion was a common finding and was associated with temporary adverse effects. Although the neuroradiologist's interpretation generally agreed with the volumetric MRI measurement, the overall 15% discordance rate emphasizes the potential benefit of considering volumetric measurements, which may help clinicians correlate posttreatment symptoms with MRI findings.
More Related Videos
10:52Stereotactic Intracranial Implantation and In vivo Bioluminescent Imaging of Tumor Xenografts in a Mouse Model System of Glioblastoma Multiforme
Published on: September 25, 2012
11:09Establishing Intracranial Brain Tumor Xenografts With Subsequent Analysis of Tumor Growth and Response to Therapy using Bioluminescence Imaging
Published on: July 13, 2010
Related Concept Videos
Biological Effects of Radiation
Radiation: Applications
The average...
Absorption of Radiation
Radiation Pressure: Problem Solving
The average value of the rate of momentum transfer divided by the absorbing area represents the average force...
Generating Electromagnetic Radiations
Gene Therapy