Nonuniform Planning Target Volume Margins for Prostate Bed on the Basis of Surgical Clips on Daily Cone Beam Computed
Haijun Song1, Joseph K Salama1, William Robert Lee1
1Duke University Medical Center, Department of Radiation Oncology, Durham, North Carolina.
Purpose:
We hypothesized that the interfraction motions of the superior and inferior prostate beds differ and therefore require different margins. In this study, we used daily cone beam computed tomography (CBCT) to evaluate the motion of postprostatectomy surgical clips (separated to superior and inferior portions) within the planning target volume (PTV) to derive data-driven PTV margins.
Methods And Materials:
Our study cohort included consecutive patients with identifiable surgical clips undergoing prostate bed irradiation with daily CBCT image guidance. We identified and contoured the clips within the PTV on the planning computed tomography and CBCT scans. All CBCT scans were registered to the planning computed tomography scan on the basis of pelvic bony structures. The superior border of the pubic symphysis was used to mark the division between the superior and inferior portions.
Results:
Eleven patients with 263 CBCT scans were included in the cohort. In the left-right direction, the global mean M, systematic error Σ, and residue error σ were 0.02, 0.03, and 0.16 cm, respectively, for superior clips, and 0.00, 0.03, and 0.03 cm, respectively, for inferior clips. In the anterior-posterior direction, the corresponding values were M = 0.01, Σ = 0.25, and σ= 0.37, respectively, for superior, and M = 0.08, Σ= 0.13, σ= 0.15, respectively, for inferior. In the superior-inferior direction, the values were M =-0.06, Σ= 0.23, and σ= 0.27, respectively, for superior, and M =-0.01, Σ= 0.21, σ= 0.20, respectively, for inferior. The results of the 2-tailed F tests showed that the anterior-posterior motion is statistically different between the superior and inferior portions in the anterior-posterior direction. There is no statistical difference in the superior-inferior and lateral directions. Therefore, we propose a set of nonuniform PTV margins (based on the formula 2.5 Σ+ 0.7σ) as 0.2 cm for all prostate beds in the left-right direction, 0.7 cm for all in superior-inferior, and 0.9 to 0.4 for superior-inferior in the anterior-posterior direction.
Conclusions:
The difference in motion between the superior and inferior portions of the prostate bed is statistically insignificant in the left-right and superior-inferior directions, but statistically significant in the anterior-posterior direction, which warrants a nonuniform PTV margin scheme.
More Related Videos
10:23Author Spotlight: Three-Dimensional Cephalometric Landmark Annotation Demonstration on Human Cone Beam Computed Tomography Scans
Published on: September 8, 2023
05:37Cone Beam Intraoperative Computed Tomography-based Image Guidance for Minimally Invasive Transforaminal Interbody Fusion
Published on: August 6, 2019
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Capillary Beds
Capillaries connect arterioles, small branches of arteries, to venules,...
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Margin of Error
Classical Conditioning in Daily Life
John B. Watson and Rosalie Rayner famously demonstrated the development of fear through classical conditioning in their experiment with Little Albert. They paired the...