Roger A Winkle1, William Fleming2, R Hardwin Mead2
1Silicon Valley Cardiology, Palo Alto Medical Foundation and Sutter Health, 1950 University Avenue, Suite 160, E, Palo Alto, CA, 94303, USA. rawinkle@aol.com.
Purpose:
To compare findings in patients undergoing atrial fibrillation(AF) and/or atrial flutter(AFl) ablation after failed cut and sew (CS) vs. non-cut and sew (NCS) surgical maze.
Methods:
We compared 10 patients with prior CS to 25 with prior NCS maze undergoing catheter ablation after failed maze.
Results:
Patient demographics: Age 68.3 ± 8.7 CS vs. 68.2 ± 9.2 NCS(P = 0.977), male 70% CS vs. 72% NCS(P = 1.000), LA size 5.11 ± 0.60 cm CS vs. 4.54 ± 0.92 cm NCS(P = 0.096), sternotomy 100% CS vs. 64% of NCS(P = 0.036). Concomitant heart surgery in 100% CS and 68% NCS(P = 0.073). NCS used radiofrequency 84%, cryoablation 8%, microwave 4%, and ultrasound 4%. All maze operations targeted pulmonary vein (PV) isolation. The maze also targeted the mitral isthmus 100% CS vs. 36% NCS(P = 0.001) and the tricuspid isthmus 90% CS vs. 40% NCS (P = 0.018). Maze failure arrhythmia mechanism was AF 0% CS and 56% NCS (P = 0.0006). Nine CS pts failed for AFl and 1 for RA tachycardia. For NCS pts, 11 failed for AFl. CS isolated 94% of PVs and NCS isolated only 26% of PVs (P < 0.0005). At EPS, clinical and induced arrhythmias were ablated and non-isolated PVs were isolated. After final ablation, arrhythmia-free rates were 60% for CS and 52% for NCS (P = 0.723) after 2.99 ± 2.35 years.
Conclusions:
After failed surgical maze, CS isolated nearly all PVs and NCS never isolated all PVs and the clinical rhythm was more frequently AF for NCS and AFl for CS. CS remains the surgical gold standard for durable PV isolation.
Related Concept Videos
Cut-off Frequency of BJT
Alpha Cut-Off Frequency: Pertinent to the common-base configuration, the alpha cut-off frequency defines the upper-frequency limit at which the current gain, alpha, remains stable. As...
Brick Cutting Techniques
Cut bricks are categorized by size. Bricks cut to half their original length are called half-bats, while those cut to three-fourths their length are known as three-fourth bats.
Special types of...
Hypothesis: Accept or Fail to Reject?
There are two ways to indicate that the null hypothesis is not rejected. 'Accept' the null...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Evolutionary Relationships through Genome Comparisons