Related Experiment Video
Updated: Jan 30, 2026

Eye Movement Monitoring of Memory
Published on: August 15, 2010
Development and validation of a high-speed video system for measuring saccadic eye movement
Jeffrey S Brooks1, William J Smith1, Brandon M Webb1
1School of Kinesiology, Faculty of Health Sciences, Western University, London, Ontario, Canada.
Abstract:
Laboratory-based retroreflective and magnetic scleral search-coil technologies are the current standards for collecting saccadometric data, but such equipment is costly and cumbersome. We have validated a novel, portable, high-speed video camera-based system (Exilim EX-FH20, Casio, Tokyo, Japan) for measuring saccade reaction time (RT) and error rate in a well-lit environment. This system would enable measurements of pro- and antisaccades in athletes, which is important because antisaccade metrics provide a valid tool for concussion diagnosis and determining an athlete's safe return to play. A total of 529 trials collected from 15 participants were used to compare saccade RT and error rate measurements of the high-speed camera system to a retroreflective video-based eye tracker (Eye-Trac 6: Applied Sciences Laboratories, Bedford, MA). Bland-Altman analysis revealed that the RT measurements made by the high-speed video system were 11 ms slower than those made by the retroreflective system. Error rate measurements were identical between the two systems. An excellent degree of reliability was found between the system measurements and in the ratings of independent researchers examining the video data. A strong association (r = .97) between the RTs determined via the retroreflective and high-speed camera systems was observed across all trials. Our high-speed camera system is portable and easily set up, does not require extensive equipment calibration, and can be used in a well-lit environment. Accordingly, the camera-based capture of saccadometric data may provide a valuable tool for neurological assessment following a concussive event and for the continued monitoring of recovery.
More Related Videos
06:46Investigating the Deployment of Visual Attention Before Accurate and Averaging Saccades via Eye Tracking and Assessment of Visual Sensitivity
Published on: March 18, 2019
05:54Eye-tracking to Distinguish Comprehension-based and Oculomotor-based Regressive Eye Movements During Reading
Published on: October 18, 2018
Related Concept Videos
Reliability and Validity
In Vitro Drug Release Testing: Overview, Development and Validation
Anatomical Movements
Here are some common anatomical movements:
Flexion and extension motions are in the sagittal (anterior–posterior) plane of motion. These movements take place at the shoulder, hip, elbow, knee, wrist,...
Data Validation
Key parameters for method validation include:
Data Validation
Nursing assessment guides are generally based on holistic models rather than medical...
Speed of Sound in Gases