Related Experiment Video
Updated: Jan 30, 2026

A Novel Bayesian Change-point Algorithm for Genome-wide Analysis of Diverse ChIPseq Data Types
Published on: December 10, 2012
Assessment of a Novel Algorithm to Determine Change-of-Direction Angles While Running Using Inertial Sensors
Aaron S Balloch1,2, Mahir Meghji3, Robert U Newton1,4
1School of Medical and Health Sciences, Edith Cowan University, Perth, Western Australia, Australia.
Abstract:
Balloch, AS, Meghji, M, Newton, RU, Hart, NH, Weber, JA, Ahmad, I, and Habibi, D. Assessment of a novel algorithm to determine change-of-direction angles while running using inertial sensors. J Strength Cond Res 34(1): 134-144, 2020-The ability to detect and quantify change-of-direction (COD) movement may offer a unique approach to load-monitoring practice. Validity and reliability of a novel algorithm to calculate COD angles for predetermined COD movements ranging from 45 to 180° in left and right directions was assessed. Five recreationally active men (age: 29.0 ± 0.5 years; height: 181.0 ± 5.6 cm; and body mass: 79.4 ± 5.3 kg) ran 5 consecutive predetermined COD trials each, at 4 different angles (45, 90, 135, and 180°), in each direction. Participants were fitted with a commercially available microtechnology unit where inertial sensor data were extracted and processed using a novel algorithm designed to calculate precise COD angles for direct comparison with a high-speed video (remotely piloted, position-locked aircraft) criterion measure. Validity was assessed using Bland-Altman 95% limits of agreement and mean bias. Reliability was assessed using typical error (expressed as a coefficient of variation [CV]). Concurrent validity was present for most angles. Left: (45° = 43.8 ± 2.0°; 90° = 88.1 ± 2.0°; 135° = 136.3 ± 2.1°; and 180° = 181.8 ± 2.5°) and Right: (45° = 46.3 ± 1.6°; 90° = 91.9 ± 2.2°; 135° = 133.4 ± 2.0°; 180° = 179.2 ± 5.9°). All angles displayed excellent reliability (CV < 5%) while greater mean bias (3.6 ± 5.1°, p < 0.001), weaker limits of agreement, and reduced precision were evident for 180° trials when compared with all other angles. High-level accuracy and reliability when detecting COD angles further advocates the use of inertial sensors to quantify sports-specific movement patterns.
Related Concept Videos
Inertial Frames of Reference
Non-inertial Frames of Reference
Wald-Wolfowitz Runs Test II
For binary data, runs are identified using symbols such as + and −, or equivalently, 1s and 0s. In...
Wald-Wolfowitz Runs Test I
The test works...
Contact Angle
The adhesive force is the molecular force between molecules of different materials, that is, between the molecules of the solid and the liquid. The cohesive...
Trial and Error and Algorithm

