Validation of the Cosmed K4b2 Portable Metabolic System During Running Outdoors
Ramzy Ross1, Anas ALDuhishy2, Carlos González-Haro3
1Institute of Cardiovascular and Medical Sciences, University of Glasgow, Glasgow, United Kingdom.
Abstract:
Ross, R, ALDuhishy, A, and González-Haro, C. Validation of the cosmed K4b2 portable metabolic system during running outdoors. J Strength Cond Res 34(1): 124-133, 2020-The aim of this study was to determine the agreement of the K4b metabolic system in comparison with the Douglas bags (DB) method for determining gas-exchange variables during both indoor treadmill and outdoor running. Nineteen endurance-trained males undertook 3 maximal incremental running tests, separated by at least 2 days: K4b indoor test (K1), K4b outdoor test (K2), and DB indoor test. Gas-exchange parameters (VO2, VCO2, VE, VI, Respiratory Exchange Ratio, FEO2, and FECO2) and heart rate were measured during K1, K2, and DB tests. For most of the variables (VO2, %VO2, %VCO2, VE, and VI), the agreement was better for K2 when compared with DB than for K1 when compared with DB. For VCO2, FEO2, and FECO2, the agreement was better between K1 when compared with DB than for K2 when compared with DB. Respiratory Exchange Ratio showed a similar agreement between both conditions (K1 vs. DB and K2 vs. DB). K4b seems valid for measuring gas-exchange variables during submaximal and maximal running velocities in an outdoor environment. Although K2 mean systematic error (bias) was low, the aleatory error was moderate. These considerations should be taken into account when using K4b to measure gas-exchange parameters both during indoor and outdoor activities.
More Related Videos
04:48Tracking Individual Running Metrics in Mice Using a Voluntary Wheel Running Protocol that Minimizes Social Isolation
Published on: April 18, 2025
14:17The Portable Chemical Sterilizer PCS, D-FENS, and D-FEND ALL: Novel Chlorine Dioxide Decontamination Technologies for the Military
Published on: June 29, 2014
Related Concept Videos
Reliability and Validity
Wald-Wolfowitz Runs Test II
For binary data, runs are identified using symbols such as + and −, or equivalently, 1s and 0s. In...
What is Metabolism?
Wald-Wolfowitz Runs Test I
The test works...
Data Validation
Key parameters for method validation include:
Data Validation
Nursing assessment guides are generally based on holistic models rather than medical...