Related Experiment Video
Updated: Jan 30, 2026

Preparation of Aligned Steel Fiber Reinforced Cementitious Composite and Its Flexural Behavior
Published on: June 27, 2018
Experimental Investigation on Columns of Steel Fiber Reinforced Concrete with Recycled Aggregates under Large
Changyong Li1, Haibin Geng2, Caiheng Deng3
1School of Civil Engineering and Communications, North China University of Water Resources and Electric Power, Zhengzhou 450045, China. lichang@ncwu.edu.cn.
Abstract:
To improve the structural application of steel fiber-reinforced concrete with recycled aggregates (SFRC-RA) composited in gradation by large-particle natural coarse aggregate and small-particle recycled coarse aggregate, the large eccentric compression behavior of eight SFRC-RA columns was experimentally investigated in this paper. The main parameters considered were the strength of the SFRC-RA and the volume fraction of the steel fiber. Details about the sectional concrete strain, the longitudinal steel bar strain, the lateral displacement, the cracking load, the crack distribution and crack width, and the ultimate load of the SFRC-RA columns were measured. The beneficial effects of steel fiber on these attributes were discussed, and the ductility corresponding to the lateral displacement of the SFRC-RA columns was also analyzed. Based on the test results and design principles, formulas were proposed for predicting the cracking resistance, crack width, and lateral displacement of SFRC-RA columns in a normal service state. The ultimate loads of the SFRC-RA columns under a large eccentric compression load were calculated, considering the second-order effects.
More Related Videos
Related Concept Videos
Design of Columns under an Eccentric Load
Fiber Reinforced Concrete
Behavior of Concrete Under Compressive Load
As the concrete specimen fractures under...
Eccentric Loading
Reinforcements in Concrete
General Case of Eccentric Axial Loading
Consider a member subjected to equal and opposite forces that are applied along a line that does not coincide with the member's neutral axis. In unsymmetrical...