Experimental Design Approach to Optimize HPLC Separation of Active Ingredients, Preservatives, and Colorants in Syrup
Şule Dinç-Zor1, Bürge Aşçi1, Özlem Aksu Dönmez1
1Yildiz Technical University, Davutpasa Campus, Department of Chemistry, Istanbul 34220, Turkey.
Abstract:
Background: Preservatives and colorants in pharmaceutical products may be highly toxic, especially for sensitive individuals, when they are used in excessive amounts. In this context, sensitive and non-labor-intensive analytical methods with short analysis time for simultaneous quantification of these additive substances in drugs can meet all requirements in quality control laboratories. Objective: The aim of the study was to develop a simultaneous HPLC method for the analysis of pseudoephedrine HCl and guaifenesin, along with preservatives, methyl paraben and propyl paraben, and colorants, ponceau 4R and sunset yellow, in a syrup sample. Methods: Optimum conditions of HPLC separation were determined by Box-Behnken experimental design. Four independent variables of the separation were pH (6.0, 6.5, and 7.0) and flow rate of the mobile phase (2.0, 2.2, and 2.4 mL/min) and mobile phase ratios for the first and second gradient elutions (75, 80, and 85% for Gradient 1 and 50, 55, and 60% for Gradient 2 in terms of phosphate buffer percent, respectively). Results: The optimum conditions were found to be pH, 6.3; flow rate, 2.4 mL/min; and mobile phase ratios (phosphate buffer-acetonitrile) for Gradient 1 and 2, 85+15 (v/v) and 60+40 (v/v), respectively. Conclusions: Simultaneous analysis of all compounds was achieved by using this HPLC method with a short run time below 10 min. Highlights: This simple, rapid, and validated method is convenient and applicable for routine analysis of pharmaceutical products having similar composition without the need for any extraction step.
More Related Videos
10:25Construction of Models for Nondestructive Prediction of Ingredient Contents in Blueberries by Near-infrared Spectroscopy Based on HPLC Measurements
Published on: June 28, 2016
07:22Author Spotlight: Unraveling the Role of Earthworms in Enhancing Mineral Weathering for CO2 Removal
Published on: November 10, 2023
Related Concept Videos
Experimental Designs
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Dosage Regimens: Designs and Approaches
Factorial Design
Group Design
Bioequivalence Experimental Study Designs: Completely Randomized and Randomized Block Designs
