Related Experiment Video
Updated: Jan 30, 2026

Loop-Mediated Isothermal Amplification for Screening Salmonella in Animal Food and Confirming Salmonella from Culture Isolation
Published on: May 20, 2020
Inductively Coupled Plasma-Mass Spectrometric Determination of Iodine in Food Using Tetramethyl Ammonium Hydroxide
Todor I Todorov1, Yunseol Kim1, Jennifer Fong Sam1
1U.S. Food and Drug Administration, Center for Food Safety and Applied Nutrition, 5001 Campus Dr, HFS 716, College Park, MD 20740.
Abstract:
Background: The performance of U.S. Food and Drug Administration (FDA) Elemental Analysis Manual (EAM) 4.13 method (Inductively Coupled Plasma-Mass Spectrometric Determination of Iodine in Food Using Tetramethyl Ammonium Hydroxide Extraction) was tested in an interlaboratory study. Objective: The aim of the study is to demonstrate that the FDA EAM method 4.13 is applicable for the analysis of food and multivitamins. Methods: Six collaborators participated in the study using four different models of inductively coupled plasma-mass spectrometry instruments. The method evaluation included determination of the limits of detection and quantification, analysis of National Institute of Standards and Technology standard reference materials (SRMs), unknown samples, blinded SRMs, and fortified analytical portions by all six collaborators. The samples were chosen to represent all sectors of the AOAC food triangle and additionally included pet food and multivitamin tablets. Results: The repeatability and reproducibility ranges were 1.8-11.4% and 3.6-13.7%, respectively; the calculated HorRat values were in the 0.17-1.18 range; and 174 of 175 SRM analyses had z-scores <2 and fortified analytical portion samples with recoveries of 102-105%, indicating acceptable method performance. Conclusions: The study supports a Level Three Multilaboratory Validation according to FDA Food and Veterinary Program Guidelines performed by six collaborators using six certified reference materials and nine unknown samples. Highlights: The method is applicable for quantification of the total extractable iodine in food and multivitamin dietary supplements.
Related Concept Videos
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Pharmacokinetics: Drug–Food and Drug–Viral Interactions
Regulation of Food Intake
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Microorganisms in Agriculture and Food industry

