123I-MIBG scintigraphy utility and cut-off value in a clinically representative dementia cohort
J P M Kane1, G Roberts2, G S Petrides3
1Institute of Neuroscience, Newcastle University, Biomedical Research Building, Campus for Ageing and Vitality, Newcastle University, Newcastle upon Tyne, NE4 5PL, United Kingdom.
Objective:
To determine the utility of 123I-metaiodobenzylguanidine cardiac scintigraphy (MIBG), and optimum heart: mediastinum ratio (HMR) for differentiating dementia with Lewy bodies (DLB) from Alzheimer's disease (AD) in a clinically representative population, comparing findings with those of 123I-2β -carbomethoxy-3β-(4-iodophenyl)-N-(3-fluoropropyl) nortropane (FP-CIT) SPECT.
Methods:
We recruited subjects with probable DLB (n = 17) and probable AD (n = 16) from clinical services. Each participant underwent clinical examination, cardiac MIBG scintigraphy and FP-CIT SPECT. Diagnosis was made on the basis of clinical symptoms using validated criteria. Cardiac MIBG uptake was measured by the planar HMR, blind to clinical diagnosis, with values below a cut-off taken from a previous study (<2.2 at four hours) defining scans as abnormal. FP-CIT scans were blindly rated according to a visual rating scale.
Results:
MIBG had a sensitivity, specificity and overall accuracy of 71%, 81% and 76% for distinguishing DLB from AD. FP-CIT demonstrated a sensitivity, specificity and accuracy of 82%, 88% and 85%. Using a lower HMR cut-off to distinguish between abnormal and normal MIBG scans improved the accuracy of MIBG, raising specificity (100%) and overall accuracy (85%) without compromising sensitivity (71%). Neither prescription of potentially interfering medications, nor a history of myocardial infarction (MI), had a significant effect on HMR.
Conclusion:
We found that MIBG did not demonstrate superior sensitivity and overall accuracy to FP-CIT. HMR cut-off influences biomarker utility, and clinical and Caucasian populations may require a lower cut-off than those reported elsewhere. Future MIBG studies should include clinically representative cohorts as neither medications nor previous MI appear to influence HMR.
Related Concept Videos
Dementia
The progression of dementia is generally gradual....
The Representativeness Heuristic
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Cut-off Frequency of BJT
Alpha Cut-Off Frequency: Pertinent to the common-base configuration, the alpha cut-off frequency defines the upper-frequency limit at which the current gain, alpha, remains stable. As...
Brick Cutting Techniques
Cut bricks are categorized by size. Bricks cut to half their original length are called half-bats, while those cut to three-fourths their length are known as three-fourth bats.
Special types of...
Nursing Clinical Information System
A Nursing Clinical Information System (NCIS) is a specialized type of healthcare information system tailored to meet the unique needs of nursing practice. It incorporates the principles of nursing informatics to streamline information management and improve the quality of care delivery.
Critical attributes of NCIS include: