Related Experiment Video
Updated: Jan 29, 2026

A Dual Tracer PET-MRI Protocol for the Quantitative Measure of Regional Brain Energy Substrates Uptake in the Rat
Published on: December 28, 2013
Optimal timing of tau pathology imaging and automatic extraction of a reference region using dynamic [18F]THK5317 PET
My Jonasson1, Anders Wall2, Konstantinos Chiotis3
1Department of Surgical Sciences, Uppsala University, Uppsala, Sweden; Medical Physics, Uppsala University Hospital, Uppsala, Sweden.
Abstract:
[18F]THK5317 is a PET tracer for in-vivo imaging of tau associated with Alzheimer's disease (AD). This work aimed to evaluate optimal timing for standardized uptake value ratio (SUVR) measures with [18F]THK5317 and automated generation of SUVR-1 and relative cerebral blood flow (R1) parametric images. Nine AD patients and nine controls underwent 90 min [18F]THK5317 scans. SUVR-1 was calculated at transient equilibrium (TE) and for seven different 20 min intervals and compared with distribution volume ratio (DVR; reference Logan). Cerebellar grey matter (MRI) was used as reference region. A supervised cluster analysis (SVCA) method was implemented to automatically generate a reference region, directly from the dynamic PET volume without the need of a structural MRI scan, for computation of SUVR-1 and R1 images for a scan duration matching the optimal timing. TE was reached first in putamen, frontal- and parietal cortex at 22 ± 4 min for AD patients and in putamen at 20 ± 0 min in controls. Over all regions and subjects, SUVR20-40-1 correlated best with DVR-1, R2 = 0.97. High correlation was found between values generated using MRI- and SVCA-based reference (R2 = 0.93 for SUVR20-40-1; R2 = 0.94 for R1). SUVR20-40 allows for accurate semi-quantitative assessment of tau pathology and SVCA may be used to obtain a reference region for calculation of both SUVR-1 and R1 with 40 min scan duration.
More Related Videos
08:31Visualization and Quantification of Brown and Beige Adipose Tissues in Mice using [18F]FDG Micro-PET/MR Imaging
Published on: July 1, 2021
06:31Quantitative [18F]-Naf-PET-MRI Analysis for the Evaluation of Dynamic Bone Turnover in a Patient with Facetogenic Low Back Pain
Published on: August 8, 2019
Related Concept Videos
Automatic Processing and Automatic Social Behavior
Kendall's Tau Test
A τ value of +1 indicates...
Inertial Frames of Reference
Non-inertial Frames of Reference
IR Frequency Region: Fingerprint Region
Chemical Shift: Internal References and Solvent Effects
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...