Related Experiment Video
Updated: Jan 29, 2026

Implementation of In Vitro Drug Resistance Assays: Maximizing the Potential for Uncovering Clinically Relevant Resistance Mechanisms
Published on: December 9, 2015
Implant-supported overdentures with different clinical configurations: Mechanical resistance using a numerical
Guillermo de la Rosa Castolo1, Sonia V Guevara Perez2, Pierre-Jean Arnoux3
1Doctoral student, The French Institute of Science and Technology for Transport, Development and Networks (IFSTTAR) Laboratory of Applied Biomechanics, Aix-Marseille University, Marseille, France; Research Engineer, Glad Medical SAS, Salon-de-Provence, France.
Statement Of Problem:
Implant-supported overdentures (IODs) are a treatment option for patients with complete edentulism. However, this treatment increases the possibilities of peri-implant complications, characterized by inflammation or partial loss of surrounding hard and soft tissues.
Purpose:
The purpose of this finite element analysis study was to evaluate the mechanical performance of different bar-IOD designs under different clinical configurations by comparing the stress and strain distribution on the bone during secondary stabilization.
Material And Methods:
A finite element model of the mandible representing a patient with complete edentulism was developed. Different designs of bar-IODs were modeled and compared. The parameters studied were the material properties (cobalt-chromium, zirconium dioxide, titanium grade 5, and titanium grade 4), diameter and bar-IOD cross-sectional shape, tilt of the posterior implants (30 degrees), presence of a distal extension cantilever in the bar-IODs (12 mm), and number of implants (4 or 6). Two different mastication loading conditions were analyzed. One- and 2-way ANOVAs and the Tukey honestly significant differences post hoc test (α=.05) were used to determine the significant von Mises stress and strain values in the bone.
Results:
The 4 materials tested in the bar-IOD did not have a significant mechanical effect on the bone (P<.05). A smaller diameter and structure of the bar-IOD led to significantly higher bone stress (P<.001). A distal extension cantilever led to an increased stress concentration (model M1 versus model M3: P<.001), which reached 50% in the event of tilting of the posterior implants (model M2 versus model M4: P<.001). Tilting of the posterior implants alone, without extension, had a nonsignificant effect (model M3 versus model M4: P=.999). Model M5 supported with 6 implants reduces the stress transferred to the bone compared with model M3 supported with 4 implants (P<.05).
Conclusions:
Distal extensions in bar-IODs, the tilt of the posterior implants, and the low amount of material in the cross-sectional area in the bar-IOD were the most influential parameters on the mechanical resistance of dental implants in the mandibular bone.
Related Concept Videos
Numerical Calculations
The solution to a problem is obtained using different methods. While manually solving algebraic symbols is one of the most common methods, the graphical method is often preferred. Computers...
Controller Configurations
Control-system compensation involves various configurations, most commonly series or cascade compensation, in which the controller...
Electron Configurations
The relative energies of the subshells determine the order in which atomic orbitals are filled (1s, 2s, 2p, 3s, 3p,...
Electron Configuration of Multielectron Atoms
Configurations of BJT
The common base configuration is noted for its high voltage gain, positioning it as an ideal choice for single-stage amplifier circuits, such as microphone pre-amplifiers. A notable...
Stability of Equilibrium Configuration
A stable equilibrium occurs when a system tends to return to its original position when given a small displacement, and the potential energy is at its minimum. An example of a stable equilibrium is when a cantilever beam is fixed at one end and a weight is attached to the other end. If the weight...

