Comparisons among four types of absorbable plates used for internal fixation of zygomaticomaxillary complex fractures
Seung Gyun Chu1, Joon Seok Lee1, Jeong Woo Lee1
1Department of Plastic and Reconstructive Surgery, School of Medicine, Kyungpook National University, Daegu, South Korea.
Importance:
Conventional plating systems include titanium plates for the fixation of facial bone fractures. However, titanium plates result in artifacts on computed tomography images and appear unstable on magnetic resonance images. Therefore, absorbable plates have been widely used for the fixation of facial bone fractures of late in Asia.
Objective:
To compare stability and symmetry among four different absorbable plates used for internal fixation of zygomaticomaxillary complex fractures.
Participants:
The subjects were patients with zygomaticomaxillary complex fractures that were diagnosed and treated by internal fixation with absorbable plates between January 2012 and April 2018. Patients aged ≤14 years and ≥76 years were excluded. Patients with other fracture types were also excluded. All patients underwent surgery within 2 weeks of the injury.
Intervention:
Internal fixation was performed with one of four types of absorbable plates, namely Inion®, Polymax®, Osteotrans®, and Biosorb®.
Main Outcome Measures:
The stability of the four plates was investigated by evaluation of the orbital height ratio (A'/A), zygoma angle (a'/a), distance (b'/b) from the midline, and gap (c) of the temporal process on three-dimensional facial computed tomography images obtained before, 3 weeks after, and 3-6 months after surgery. Any plate-associated complications were recorded.
Results:
In total, 400 patients were enrolled, and there were 100 patients in each of the four groups. There were no significant differences with regard to postoperative stability and relapse among the four plates. Moreover, facial symmetry showed no changes over time in any group. Complications such as infection and sensory disturbance were not frequent. All plates except Biosorb® were palpable for more than 6 months after surgery, with Osteotrans® remaining palpable for several years.
Conclusions And Relevance:
Our findings suggest that all four types of absorbable plates are useful for treating isolated zygomaticomaxillary complex fractures. While Biosorb® is unsuitable for severe comminuted fractures. Polymax® and Inion® are not bendable at room temperature. It is important to select an appropriate absorbable plate according to each patient's condition and the fracture severity.
More Related Videos
15:11Surgical Fixation of Sternal Fractures: Preoperative Planning and a Safe Surgical Technique Using Locked Titanium Plates and Depth Limited Drilling
Published on: January 5, 2015
14:29Rapid In Vivo Fixation and Isolation of Translational Complexes from Eukaryotic Cells
Published on: December 25, 2021
Related Concept Videos
Types of Receptors: Internal Receptors
Similar to membrane-bound receptors, the binding of a ligand to the intracellular receptor of causes a conformational change in the...
Internal Receptors
Internal Energy
Internal Energy
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...