Related Experiment Video
Updated: Jan 29, 2026

Cone Beam Intraoperative Computed Tomography-based Image Guidance for Minimally Invasive Transforaminal Interbody Fusion
Published on: August 6, 2019
Intraoperative verification of resection margins of maxillary malignancies by cone-beam computed tomography
O Ivashchenko1, B Pouw2, J K de Witt3
1Department of Surgical Oncology, The Netherland Cancer Institute/Antoni van Leeuwenhoek Hospital, Amsterdam, The Netherlands; Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands.
Abstract:
Resection of maxillary cancer often results in incomplete excision because of the tumour's proximity to important structures such as the orbit. To deal with this problem we prospectively investigated the feasibility of intraoperative imaging during maxillectomy to verify the planned resection margins. In total, six patients diagnosed with maxillary cancer listed for maxillectomy were included, irrespective of the histological type of tumour. Before resection, an accurate intended resection volume was delineated on diagnostic images. At the end of the operation we took a cone-beam computed tomographic (CT) scan of the treated maxilla, after which the accuracy of the resection was quantitatively evaluated by comparing the preoperative resection plan and the images acquired intraoperatively, based on the anatomy. Further resection was then done if necessary and quantitatively evaluated with a second cone-beam CT scan. Postoperatively we compared the results of the scan with those of the histological examination. Of the six, two resections were reported pathologically as less than radical, each of which was detected by intraoperative CT and resulted in extensions of the original resections. The mean (SD) distance between the planned and the actual resection was 1.49 (2.78)mm. This suggests that intraoperative cone-beam CT imaging is a promising way to make an adequate intraoperative assessment of planned surgical margins of maxillary tumours. This allows for intraoperative resection margins to be improved, possibly leading to a better prognosis for the patient.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Self-Evaluation: Self-Enhancement and Self-Verification
Strategies of Self-Presentation II: Self-Verification
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Margin of Error

