Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Interaction of EM Radiation with Matter: Spectroscopy01:12

Interaction of EM Radiation with Matter: Spectroscopy

3.2K
Electromagnetic (EM) radiation can be considered an oscillating electric and magnetic field propagating through a medium that can interact with matter in its path. The electric field in the radiation can interact with electrical charges in the atoms or molecules in the matter. On the other hand, the magnetic field can interact with the magnetic field in the atomic nucleus. The study of the interaction between electromagnetic radiation and matter is termed spectroscopy. Spectroscopy is the study...
3.2K
Interpreting R Charts01:22

Interpreting R Charts

348
R chart, or range chart, is a fundamental tool in statistical process control used to monitor the variability within a process. It complements the X-bar (x̄) chart by focusing on the range of the data, rather than individual values, providing a clear picture of the process dispersion over time.
An R chart plots the range of subsets of measurements collected from a process. Each point on the chart represents the range—defined as the difference between the maximum and minimum...
348
Interpreting Run Charts01:25

Interpreting Run Charts

3.3K
Run charts, essentially line graphs plotted over time, serve as fundamental yet effective tools for process analysis. They chronicle data sequentially, facilitating the identification of trends, shifts, or cyclical movements. This graphical representation is instrumental in determining whether a process is stable or exhibits signs of potential instability indicative of special cause variation. In the healthcare domain, run charts depict infection rates over time, enabling hospitals to monitor...
3.3K
Dual Nature of Electromagnetic (EM) Radiation01:10

Dual Nature of Electromagnetic (EM) Radiation

3.8K
Electromagnetic (EM) radiation consists of electric and magnetic field components oscillating in planes perpendicular to each other and mutually perpendicular to radiation propagation through space. EM radiation can be classified as a wave, characterized by the properties of waves such as wavelength (denoted as λ) and frequency (represented by ν).
Wavelength is the distance between two consecutive peaks (the highest point) or troughs (the lowest point) in the wave. Frequency is the number of...
3.8K
Interpretation of Confidence Intervals01:19

Interpretation of Confidence Intervals

10.0K
A confidence interval is a better estimate of the population than a point estimate, as it uses a range of values from a sample instead of a single value.
Confidence intervals have confidence coefficients that are crucial for their interpretation. The most common confidence coefficients are 0.90, 0.95, and 0.99, which can be written as percentages–90%, 95%, and 99%, respectively.
Suppose a person calculates a confidence interval with a confidence coefficient of 0.95. In that case, they can...
10.0K
Mass Spectrum: Interpretation01:24

Mass Spectrum: Interpretation

3.3K
An unknown compound can be established by identifying the molecular ion peak in the mass spectrum. The molecular ion peak is often weak or absent due to the predominance of fragmentation in high-energy electron beams. In such cases, a soft-energy electron beam can be used to scan the spectrum to enhance the intensity of the molecular ion peak. Additionally, chemical ionization, field ionization, and desorption ionization spectra are used to obtain a relatively intense molecular ion peak.To...
3.3K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Functional dissection of the prototype foamy virus glycoprotein heparan sulfate binding site.

Retrovirology·2026
Same author

Cryogenic electron tomography reveals helical organization of lipoprotein lipase in storage vesicles.

Science advances·2025
Same author

Author Correction: In situ structure of a bacterial flagellar motor at subnanometre resolution reveals adaptations for increased torque.

Nature microbiology·2025
Same author

In situ structure of a bacterial flagellar motor at subnanometre resolution reveals adaptations for increased torque.

Nature microbiology·2025
Same author

Horizontal acquisition of prokaryotic hopanoid biosynthesis reorganizes membrane physiology driving lifestyle innovation in a eukaryote.

Nature communications·2025
Same author

Cryo-EM reveals structural basis for human AIM/CD5L recognition of polymeric immunoglobulin M.

Nature communications·2024
Same journal

Towards light-coupled sample preparation for time-resolved cryoEM studies.

IUCrJ·2026
Same journal

Cryo-EM analysis of cooperative conformational changes in the SARS-CoV-2 spike protein trimer.

IUCrJ·2026
Same journal

Towards time-resolved MicroED grid preparation using mix-and-inject gas dynamic virtual nozzles.

IUCrJ·2026
Same journal

How cryoEM has advanced our understanding of bacteriophages and bacteriocins targeting Clostridioides difficile.

IUCrJ·2026
Same journal

CryoEM structures reveal allosteric regulation of the catalytic activity of the multi-protein human MAT enzyme complexes.

IUCrJ·2026
Same journal

Cryo-EM-guided subtractive optimization of a novel VCP/p97 inhibitor.

IUCrJ·2026
See all related articles

Related Experiment Video

Updated: Jan 29, 2026

Preparation of High-Temperature Sample Grids for Cryo-EM
05:05

Preparation of High-Temperature Sample Grids for Cryo-EM

Published on: July 26, 2021

4.3K

Interpreting the cryo-EM map.

Peter B Rosenthal1

  • 1Structural Biology of Cells and Viruses Laboratory, The Francis Crick Institute, 1 Midland Road, London, NW1 1AT, UK.

Iucrj
|February 5, 2019
PubMed
Summary
This summary is machine-generated.

Beckers et al. propose a novel visualization method for cryo-electron microscopy (cryo-EM) maps. This approach addresses limitations of traditional single isosurface thresholding techniques for improved map depiction.

Keywords:
cryo-EM mapelectron cryomicroscopyfalse discovery ratemap sharpeningsignal detectionsingle-particle analysissubtomogram averaging

More Related Videos

Cryo-EM and Single-Particle Analysis with Scipion
09:06

Cryo-EM and Single-Particle Analysis with Scipion

Published on: May 29, 2021

4.4K
Single-Particle Cryo-EM Data Collection with Stage Tilt using Leginon
04:52

Single-Particle Cryo-EM Data Collection with Stage Tilt using Leginon

Published on: July 1, 2022

2.8K

Related Experiment Videos

Last Updated: Jan 29, 2026

Preparation of High-Temperature Sample Grids for Cryo-EM
05:05

Preparation of High-Temperature Sample Grids for Cryo-EM

Published on: July 26, 2021

4.3K
Cryo-EM and Single-Particle Analysis with Scipion
09:06

Cryo-EM and Single-Particle Analysis with Scipion

Published on: May 29, 2021

4.4K
Single-Particle Cryo-EM Data Collection with Stage Tilt using Leginon
04:52

Single-Particle Cryo-EM Data Collection with Stage Tilt using Leginon

Published on: July 1, 2022

2.8K

Area of Science:

  • Structural Biology
  • Biophysics
  • Computational Biology

Background:

  • Cryo-electron microscopy (cryo-EM) is a powerful technique for determining the three-dimensional structure of biological macromolecules.
  • Visualization of cryo-EM density maps is crucial for interpreting structural data.
  • Conventional methods often rely on a single isosurface threshold, which can obscure fine details or introduce artifacts.

Purpose of the Study:

  • To introduce a general and improved approach for visualizing cryo-EM maps.
  • To overcome the limitations associated with single isosurface thresholding in cryo-EM map visualization.
  • To enhance the interpretability and detail representation of cryo-EM density data.

Main Methods:

  • Development of a new general methodology for cryo-EM map visualization.
  • Implementation of techniques that move beyond the constraints of a single isosurface threshold.
  • Comparative analysis against conventional visualization approaches.

Main Results:

  • The proposed method offers a more comprehensive representation of cryo-EM map features.
  • It effectively addresses challenges posed by single isosurface thresholding.
  • Enhanced visualization facilitates better interpretation of structural details.

Conclusions:

  • The novel visualization approach provides significant advantages over traditional methods for cryo-EM map analysis.
  • This technique has the potential to improve the accuracy and depth of structural insights derived from cryo-EM data.
  • Further adoption of this method could advance the field of structural biology.