Echocardiographic Evaluation of Atrial Communications before Transcatheter Closure
Published on: February 8, 2022
Strategy of treating secundum atrial septal defect not referred to percutaneous closure
Fei Zhang1, Yifeng Yang2, Qin Wu2
1NanShan people's hospital of ShenZhen, P.R. China.
Objective:
To evaluate safety and effectiveness of intraoperative device closure for secundum atrial septal defect (ASD) not referred to percutaneous closure.
Design And Patients:
From April 2010 to December 2018, 231 secundum ASD children (≤14 years) directly recommended to surgical repair were enrolled in this study. These patients were divided into two groups according to the parents' choice based on surgeons' recommendation. Follow-up evaluations were adopted at 2 weeks, 3 months, 6 months, and 12 months after the procedure and yearly thereafter. In Group A, 127 patients underwent an initial attempt at device closure. In Group B, 104 patients underwent a repair procedure under cardiopulmonary bypass.
Results:
All patients survived. Group A had lower values of operation time, mechanical ventilation time, cardiac intensive care unit duration and amount of blood transfusion. Nevertheless, postoperative hospitalization time between two groups showed no statistical difference. In group A, 109 (85.83%) patients were successfully occluded, whereas 18 (14.17%) patients were converted to open-heart surgery. No severe complications occurred in the follow-up period.
Conclusion:
Intraoperative device closure is safe, effective procedure for selected cases with secundum ASDs which were not referred to percutaneous closure because of more suitable occluder selection, no "unbutton effect" and stitching enhancement.
More Related Videos
08:00Reduction of Iatrogenic Atrial Septal Defects with an Anterior and Inferior Transseptal Puncture Site when Operating the Cryoballoon Ablation Catheter
Published on: June 15, 2015
23:33The WATCHMAN Left Atrial Appendage Closure Device for Atrial Fibrillation
Published on: February 28, 2012
Related Concept Videos
Inertial Frames of Reference
Non-inertial Frames of Reference
Lumber Defects
Shakes are minor fractures that run along or across the wood's annual rings, while wane is...
Chemical Shift: Internal References and Solvent Effects
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
Angle Closure Glaucoma: Treatment
Persuasion Strategies