Related Experiment Video
Updated: Jan 29, 2026

Fabrication of Myogenic Engineered Tissue Constructs
Published on: May 1, 2009
Construction of thermostable cellobiohydrolase I from the fungus Talaromyces cellulolyticus by protein engineering
Makoto Nakabayashi1, Saori Kamachi1, Dominggus Malle1,2
1Biomass Refinery Research Center, National Institute of Advanced Industrial Science and Technology (AIST), 3-11-32 Kagamiyama, Higashi-Hiroshima, Hiroshima, Japan.
Abstract:
Fungus-derived GH-7 family cellobiohydrolase I (CBHI, EC 3.2.1.91) is one of the most important industrial enzymes for cellulosic biomass saccharification. Talaromyces cellulolyticus is well known as a mesophilic fungus producing a high amount of CBHI. Thermostability enhances the economic value of enzymes by making them more robust. However, CBHI has proven difficult to engineer, a fact that stems in part from its low expression in heterozygous hosts and its complex structure. Here, we report the successful improvement of the thermostability of CBHI from T. cellulolyticus using our homologous expression system and protein engineering method. We examined the key structures that seem to contribute to its thermostability using the 3D structural information of CBHI. Some parts of the structure of the Talaromyces emersonii CBHI were grafted into T. cellulolyticus CBHI and thermostable mutant CBHIs were constructed. The thermostability was primarily because of the improvement in the loop structures, and the positive effects of the mutations for thermostability were additive. By combing the mutations, the constructed thermophilic CBHI exhibits high hydrolytic activity toward crystalline cellulose with an optimum temperature at over 70°C. In addition, the strategy can be applied to the construction of the other thermostable CBHIs.
Related Concept Videos
What is Genetic Engineering?
Construction of Root Locus
For positive gain values, the root locus exists on the real axis to the left of an odd number of finite open-loop poles or zeros. The root locus starts at the open-loop poles and traces the paths of the closed-loop poles as the gain...
Construction of Frequency Distribution
First, make a table with two columns—one with the title of the data that needs to be organized, and the other column for frequency. [Draw a third column for tally marks if needed]. Then, take a look at the items given in the data set and decide if an ungrouped frequency distribution table or a grouped frequency distribution table would be more suitable. If there are large sets of different values, then it is...
Bode Plots Construction
Heat Engines
Whenever we consider heat engines (and associated devices such as refrigerators and heat pumps), we do not use the standard sign convention for heat and work. For convenience, we assume that the symbols Qh, Qc, and W represent only the amounts of heat transferred...
Internal Combustion Engine

