Related Experiment Video
Updated: Jan 29, 2026

A Standardized Approach to Extra-Oral and Intra-Oral Digital Photography
Published on: July 22, 2022
A methodological approach to standardize and control the quality of the position and alignment of lamina implants on
Giovanni Battista Menchini-Fabris1,2, Ugo Covani3, Paolo Toti4,5
1Study Centre for Multidisciplinary Regenerative Research, University of Rome "G. Marconi", Via Vittoria Colonna, 11, 00193, Rome, Italy.
Objectives:
We sought to validate a new method to detect the degree of correlation between simulated and real tilted blade implants as they appear on a single two-dimensional radiograph.
Methods:
The angular correction factor (CF^) was defined as the coupling of two subsequent angle transformations, a set of five angular values describing the theoretical radiographic appearance of the blade implant: (1) three consecutive rotations about the axes of the blade ([Formula: see text], θ, and ψ, standing for pitch, roll, and yaw, respectively) to represent the polarization directions; (2) a two-dimensional projection defined by two angles (λ and [Formula: see text], respectively, longitude and latitude) to represent the vector of the X-ray beam intersecting the detector plate. Data of patients who received fixed prostheses supported by blade-form implants were employed to calculate a dimensional correction factor (CF°), a specific length through the major axis. The simulation of a distorted radiograph of a blade positioned in space was compared with the real radiograph. Differences in the angular measurements served as an initial test to assess the effectiveness of the method.
Results:
In the acquired sets of periapical radiographs, mean misalignments of + 3.58° in longitude and - 0.04° in latitude were registered. The following variations were detected during the accuracy testing: the absolute error was 0.1 ± 7.5° for angle [Formula: see text]; 2.4 ± 6.7° for angle θ; - 1.0 ± 3.7° for angle ψ; 4.5 ± 8.6° for angle λ; and 2.0 ± 9.3° for angle [Formula: see text]. The linear dependence between CF° and CF^ was estimated by a robust linear regression: slope + 0.991, intercept + 0.007, and adjusted R2 0.992.
Conclusions:
This a posteriori analysis introduces the explicit trigonometric equations of the theoretical standard (CF^) used to describe the blade implant radiographic position and misalignment on two-dimensional radiographs.
Related Concept Videos
Quality Control
Quality control helps track data, visualize trends, and identify variations, making it easier to detect deviations that may affect the accuracy of an analysis. One way to do this is by generating a quality control chart, which...
Types of Biopharmaceutical Studies: Controlled and Non-Controlled Approaches
Non-controlled studies, commonly employed for initial exploration, lack a control group, rendering them susceptible to biases and external influences. In contrast,...
Dimensional Analysis
Conversion Factors and Dimensional Analysis
The unit...
Laminins are the Adhesive Proteins of Basal Lamina
In humans, the five forms of alpha chains are LAMA 1, LAMA 2, LAMA 3, LAMA 4, and LAMA 5. The four forms of beta chains are LAMB 1, LAMB 2, LAMB 3, and LAMB 4. The three forms of gamma...
Basal Lamina are the Specialized Form of ECM
Proteins...
Type IV Collagen of Basal Lamina
A type IV collagen molecule has six alpha chains which can...

