Related Experiment Video
Updated: Jan 29, 2026

Experimental Model of Ligature-Induced Peri-Implantitis in Mice
Published on: May 17, 2024
Ligature-Induced Peri-implant Bone Loss Around Loaded Zirconia and Titanium Implants
Purpose:
To radiographically investigate ligature-induced peri-implant bone loss around loaded titanium (Ti-SLA) and zirconia (ZrO2-ZLA) implants using a canine model.
Materials And Methods:
Forty sandblasted and acid-etched titanium and zirconia implants were alternately placed in the mandibles of five canines (20 Ti-SLA, 20 ZrO2-ZLA). Implants were restored after 6 weeks of unloaded healing. After 4 weeks of functional loading, oral hygiene procedures were stopped and experimental peri-implant bone loss was initiated by placing cotton ligatures. After 8 weeks of active progression, ligatures were removed and plaque was allowed to accumulate for another 16 weeks of spontaneous progression (without ligatures). Standardized radiographs were taken at implant placement, at functional loading, and every 2 weeks during active and spontaneous progression of bone loss.
Results:
Before ligature placement, all implants were successfully osseointegrated and no clinical or radiographic signs of peri-implant infections were detectable. Two weeks after ligature removal, one titanium implant was lost; however, no zirconia implant failures were observed during the study. Radiographically, zirconia implants revealed statistically significantly less crestal peri-implant bone loss compared to titanium implants at the end of the active progression period (Ti-SLA: 3.92 mm; ZrO2-ZLA: 2.65 mm; P < .01); however, no significant differences occurred after the spontaneous progression period (P = .6). Combining the active and spontaneous progression periods together, zirconia implants demonstrated significantly reduced peri-implant bone loss compared to titanium implants (Ti-SLA: 3.76 mm; ZrO2-ZLA: 2.42 mm; P < .01).
Conclusion:
These results demonstrate a significantly reduced ligature-induced inflammation and bone loss for ZrO2-ZLA implants compared to Ti-SLA implants in the canine model.
Related Concept Videos
Line Loss
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
Energy Losses in Transformers
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
Major Losses in Pipes
Fluid flow can be classified as laminar or turbulent, primarily based on the Reynolds number. This dimensionless number reflects the relative influence of inertial to viscous...
Minor Losses in Pipes
Valves play a significant role in generating minor losses by obstructing or redirecting the fluid flow. When a valve is closed or partially closed, it restricts the flow...
Impact Loading