Related Experiment Video
Updated: Jan 29, 2026

Author Spotlight: An Alternative Approach to Protein Quantification by Bradford Assay Using a Smartphone
Published on: September 8, 2023
Comparison of different smartphone cameras to evaluate conjunctival hyperaemia in normal subjects
Carles Otero1, Nery García-Porta2, Juan Tabernero2
1Vision and Eye Research Unit, School of Medicine, Anglia Ruskin University, Cambridge, UK. carles.otero@anglia.ac.uk.
Abstract:
Despite the significant advantages that smartphones' cameras can provide in teleophthalmology and artificial intelligence applications, their use as black-box systems for clinical data acquisition, without adequate information of the quality of photographs can compromise data accuracy. The aim of this study is to compare the objective and subjective quantification of conjunctival redness in images obtained with calibrated and non-calibrated cameras, in different lighting conditions and optical magnifications. One hundred ninety-two pictures of the eye were taken in 4 subjects using 3 smartphone cameras{Bq, Iphone, Nexus}, 2 lighting levels{high 815 lx, low 122 lx} and 2 magnification levels{high 10x, low 6x}. Images were duplicated: one set was white balanced and color corrected (calibrated) and the other was left as it was. Each image was subjective and objectively evaluated. There were no significant differences in subjective evaluation in any of the conditions whereas many statistically significant main effects and interaction effects were shown for all the objective metrics. The clinician's evaluation was not affected by different cameras, lighting conditions or optical magnifications, demonstrating the effectiveness of the human eye's color constancy properties. However, calibration of a smartphone's camera is essential when extracting objective data from images.
Related Concept Videos
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Normal Stress
When a rod is under axial loading, the internal forces and corresponding stress are normal to the plane of the section, so it is termed normal stress. It's important to...
Normal Distribution
Variation: Normal Distribution, Range, and Standard Deviation
Cable Subjected to Its Own Weight
A generalized loading function is employed to analyze a cable subjected to its own weight. This function considers the force acting along the cable's arc length rather than its projected length, providing a more accurate...
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...

