Related Experiment Video
Updated: Jan 29, 2026

An All-in-one Sample Holder for Macromolecular X-ray Crystallography with Minimal Background Scattering
Published on: July 6, 2019
Inversion-free image recovery from strong aberration using a minimally sampled transmission matrix
Kwanjun Park1, Taeseok Daniel Yang2, Hyung-Jin Kim1
1Department of Bio-convergence Engineering, Korea University, Seoul, 02841, South Korea.
Abstract:
A transmission matrix (TM), a characteristic response for an input-output relation of an optical system, has been used for achieving diffraction-limited and aberration-free images through highly-aberrant imaging systems. However, its requirement of acquiring a huge-size TM along with its heavy computational load limit its widespread applications. Here we propose a method for TM-based image reconstruction, which is more efficient in terms of data manipulation and computational time. Only 10% of the TM elements for a fish-eye (FE) lens with strong aberration were sampled compared to that required for the image reconstruction by the conventional inversion method. The missing information was filled in by an iterative interpolation algorithm working in k-space. In addition, as a replacement of the time-consuming matrix inversion process, a phase pattern was created from the minimally sampled TM in order to compensate for the angle-dependent phase retardation caused by the FE lens. The focal distortion could be corrected by applying the phase correction pattern to the angular spectrums of the measured object images. The remaining spatial distortion could also be determined through the geometrical transformation also determined by the minimally sampled TM elements. Through the use of these procedures, the object image can be reconstructed 55 times faster than through the use of the usual inversion method using the full-sized TM, without compromising the reconstruction performances.
Related Concept Videos
Titration Calculations: Strong Acid - Strong Base
A titration is carried out for 25.00 mL of 0.100 M HCl (strong acid) with 0.100 M of a strong base NaOH. The pH at different volumes of added base solution can be calculated as follows:
(a) Titrant volume = 0 mL. The solution pH is due to the acid ionization of HCl. Because this is a strong acid, the ionization is complete and the hydronium ion molarity is 0.100 M. The pH of the solution is then:
Strong Acid and Base Solutions
Titration of a Strong Acid with a Strong Base
The Extracellular Matrix
Inverse Trigonometric Functions
Inverse Hyperbolic Functions and Their Derivatives

