Dose evaluation indices for total body irradiation using TomoDirect with different numbers of ports: A comparison
Yuki Kasai1, Yukihide Fukuyama2, Hiromi Terashima2
1Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka City, Fukuoka, 812-8582, Japan.
Abstract:
TomoDirect has been reported to have some advantages over TomoHelical in delivering total body irradiation (TBI). This study aimed to investigate the relationships between the number of ports and the dose evaluation indices in low-dose TBI in TomoDirect mode using 2-12 ports and to compare these data with those for the TomoHelical mode in a simulation study. Thirteen patients underwent low-dose TBI in TomoHelical mode from June 2015 to June 2016. We used the same computed tomography data sets for these patients to create new treatment plans for upper-body parts using TomoDirect mode with 2-12 beam angles as well as TomoHelical mode. The prescription was 4 Gy in two equal fractions. For the TomoDirect data, we generated plans with 2-12 ports with approximately equally spaced angles; the modulation factor, field width, and pitch were 2.0, 5.0 cm, and 0.500, respectively. For the TomoHelical plans, the modulation factor, field width, and pitch were 2.0, 5.0 cm, and 0.397, respectively. D2, D98, D50, and the homogeneity index (HI) were evaluated to compare TomoDirect plans having 2-12 ports with the TomoHelical plan. Using TomoDirect plans, D2 with four ports or fewer, D98 with 10 ports or fewer, D50 with four ports or fewer and HI with five ports or fewer showed statistically significantly worse results than the TomoHelical plan. With the TomoDirect plans, D2 with seven ports or more, D50 with eight ports or more, and HI with eight ports or more showed statistically significant improvement compared with the TomoHelical plan. All of the dose evaluation indices of the TomoDirect plans showed a tendency to improve as the number of ports increased. TomoDirect plans showed statistically significant improvement of D2, D50, and HI compared with the TomoHelical plan. Therefore, we conclude that TomoDirect can provide better dose distribution in low-dose TBI with TomoTherapy.
More Related Videos
Related Concept Videos
Indicators
Dose Size and Dosing Frequency: Determination Methods
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses
Rational Dosage Regimen: Maintenance Dose and Loading Dose
In most cases, drugs are administered repetitively or infused continuously to maintain a steady-state concentration in the body. At a steady...