Related Experiment Video
Updated: Jan 29, 2026

Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
Edoxaban plasma levels in patients with non-valvular atrial fibrillation: Inter and intra-individual variability,
Sophie Testa1, Claudia Dellanoce1, Oriana Paoletti1
1Haemostasis and Thrombosis Center, Hospital of Cremona, ASST Cremona, Italy.
Background:
High inter-individual variability of the anticoagulant plasma levels of the first three direct oral anticoagulants was previously reported. Aims of the present study were to evaluate edoxaban inter and intra-individual variability in patients with non valvular atrial fibrillation and to assess correlation between edoxaban plasma levels and coagulation screening test and renal function.
Methods:
From January 31st 2017 to June 30th 2018, a total of 101 NVAF patients were enrolled: 48 patients were on edoxaban 60 mg and 53 on edoxaban 30 mg, once daily. Blood samples were taken at C-trough and at C-peak within the first month (15-25 days) of treatment and then at C-trough each three months. Prothrombin time (PT), activated partial thromboplastin time (aPTT), specific anti-FXa chromogenic test were performed. Creatinine clearance (CrCl) was calculated using the Cockcroft-Gault formula.
Results:
Mean inter-individual variability expressed as overall coefficient of variation (CV%) values was lower at C-peak (CV% = 49) than at C-trough (CV% = 68). Mean CV% intra-individual variability was 26.5. No significant correlation was found between edoxaban plasma levels and CrCl (C-trough r/r2 = -0.007/0.000; C-peak r/r2 = 0.129/0.017). Correlations (r/r2), at C-trough and C-peak, between edoxaban levels and PT and aPTT, were 0.386/0.149-0.922/0.851 and 0.283/0.080-0.567/0.321, respectively. Significant discrepancies between PT or aPTT and edoxaban levels were found.
Conclusions:
This study confirms also for edoxaban a high inter-individual variability in NVAF patients. PT and aPTT are not useful to measure this drug. As for the other two anti-FXa drugs, the absence of a significant correlation between CrCl and edoxaban plasma levels was observed.
More Related Videos
Related Concept Videos
Factors Affecting Renal Clearance: Drug's Physicochemical Properties and Plasma Levels
One important factor is the drug's molecular size. The kidneys readily excrete smaller molecules below 300 Daltons (Da). On the other hand, molecules weighing between 300 and 500 Da are excreted through both urine and bile. Larger molecules above 500 Da tend to be excreted...
Amyloid Fibrils
Amyloid deposits were observed as early as 1639 in the liver and the spleen. In 1854, Rudolph Virchow performed iodine staining,...
Amyloid Fibrils
Correlations
Correlation and Causation
Correlation versus Causation
If the dependent variable increases or decreases when the independent variable increases, there is a positive or negative...
Coagulation