Related Experiment Video
Updated: Jan 29, 2026

Microfocus X-ray CT microCT Imaging of Actinia equina Cnidaria, Harmothoe sp. Annelida, and Xenoturbella japonica Xenacoelomorpha
Published on: August 6, 2019
Absolute Configuration of Bioactive Azaphilones from the Marine-Derived Fungus Pleosporales sp. CF09-1
Fei Cao1, Zhi-Hui Meng1, Xing Mu2
1College of Pharmaceutical Sciences, Key Laboratory of Pharmaceutical Quality Control of Hebei Province, Key Laboratory of Medicinal Chemistry and Molecular Diagnostics of Education Ministry of China , Hebei University , Baoding 071002 , People's Republic of China.
Abstract:
Investigation of the marine-derived fungus Pleosporales sp. CF09-1 cultured in modified PDB medium led to the isolation of six new azaphilone derivatives, pleosporalones B and C (1 and 2) and pleosporalones E-H (4-7), and one known analogue (3). The absolute configurations of C-2' and C-3' in 3 were assigned by a vibrational circular dichroism method. The C-11 relative configurations for the pair of C-11 epimers (4 and 5) were established by comparing the magnitude of the computed 13C NMR chemical shifts (Δδcalcd) with the experimental 13C NMR values (Δδexp) for the epimers. Antiphytopathogenic and anti- Vibrio activities were evaluated for 1-7. Pleosporalone B (1) exhibited potent antifungal activities against the fungi Alternaria brassicicola and Fusarium oxysporum with the same MIC value of 1.6 μg/mL, which were stronger than the positive control ketoconazole among these compounds. Additionally, pleosporalone C (2) displayed significant activity against the fungus Botryosphaeria dothidea (MIC, 3.1 μg/mL). Compounds 6 and 7 displayed moderate anti- Vibrio activities against Vibrio anguillarum and Vibrio parahemolyticus, with MIC values of 13 and 6.3 μg/mL for 6 and 6.3 and 25 μg/mL for 7, respectively.
Related Concept Videos
Electron Configuration of Multielectron Atoms
Controller Configurations
Control-system compensation involves various configurations, most commonly series or cascade compensation, in which the controller...
Electron Configurations
The relative energies of the subshells determine the order in which atomic orbitals are filled (1s, 2s, 2p, 3s, 3p,...
Absolute Value Inequalities
Mean Absolute Deviation
Let us consider a dataset containing the number of unsold cupcakes in five shops: 10, 15, 8, 7, and 10. Initially, calculate the sample mean. Then calculate the deviation, or the difference, between each data value and the mean. Next, the absolute values of these deviations are added and divided by the sample size to...
Configurations of BJT
The common base configuration is noted for its high voltage gain, positioning it as an ideal choice for single-stage amplifier circuits, such as microphone pre-amplifiers. A notable...

