Related Experiment Video
Updated: Jan 29, 2026

Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
In vivo analysis of two new fungicides in mung bean sprouts by solid phase microextraction-gas chromatography-mass
Zhen Shi1, Dan Chen1, Tian-Tian Chen1
1Key Laboratory of Pesticide & Chemical Biology, Ministry of Education, College of Chemistry, Central China Normal University, Wuhan, China.
Abstract:
A novel solid phase microextraction-gas chromatography-mass spectrometry (SPME-GC-MS) method was developed to quantify two new fungicide residuals (Y13149, Y12196) in mung bean sprouts. With a stable and biocompatible elcetrospinning nanofiber (polystyrene/graphene@silica, PS/G@SiO2) as coating, the SPME fiber was directly inserted into the stem of mung bean sprout to in-situ in-vivo sampling and extraction, followed by GC-MS analysis. Under the optimal conditions, satisfactory average recoveries of 99% and 72% were obtained for Y13149 and Y12196 with the relative standard deviations (RSDs) under 16.3%, indicating good precision and anti-matrix ability of the method. The result also exhibited low detection limit (0.06-0.08 μg·L-1) and wide liner range (0.3-100 μg·L-1) with the correlation coefficients (R2) of 0.9989. The established method was applied successfully to trace the accumulation and distribution of fungicides in mung bean sprouts, and it provides a simple, rapid and reliable quantitative method for food analysis.
More Related Videos
05:29Profiling Volatile Compounds in Blackcurrant Fruit using Headspace Solid-Phase Microextraction Coupled to Gas Chromatography-Mass Spectrometry
Published on: June 9, 2021
09:09Semi-Quantitative Analysis of Peptidoglycan by Liquid Chromatography Mass Spectrometry and Bioinformatics
Published on: October 13, 2020
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II