Related Experiment Video
Updated: Jan 29, 2026

Mass-Sensitive Particle Tracking to Characterize Membrane-Associated Macromolecule Dynamics
Published on: February 18, 2022
Modelling permeation passive sampling: intra-particle resistance to mass transfer and comprehensive sensitivity
Faten Salim1, Marios Ioannidis, Alexander Penlidis
1University of Waterloo, Department of Chemistry, 200 University Avenue West, Waterloo, ON, Canada N2L 3G1. tgórecki@uwaterloo.ca.
Abstract:
A mathematical model developed previously to describe the sampling process in permeation passive samplers with non-porous adsorbents and evaluated using the Waterloo Membrane Sampler (WMS) is here extended to include adsorbents with porous particles. This work was motivated by the need to expand the model applicability to include the various types of adsorbents used in the WMS, and to develop a deep understanding of the model sensitivity towards required parameters. The effects of intraparticle porosity on the effective diffusivity of the analyte in a bed of porous particles and on the mass transfer coefficient for analyte transport from the interparticle void phase to the porous solid phase are both evaluated. Experimental validation of the applicability of the model on adsorbents with microporous particles was carried out using the WMS containing Anasorb 747, a carbon-based adsorbent with highly porous particles. Good agreement between the experimental and model results was found. A comprehensive sensitivity analysis was also conducted to identify the parameters with the greatest influence on the results of the calculated uptake rate. This analysis included two types of adsorbents with different sorption strengths. The results showed that the uptake rate sensitivity is limited to parameters related to mass transfer in the membrane for strong adsorbents. On the other hand, sensitivity to parameters related to mass transfer in the sorbent bed becomes more significant as the strength of the adsorbent decreases; however, this effect can be reduced by increasing the membrane thickness. Influential parameters in the sorbent bed are also affected by the temperature. Nevertheless, the contribution of this change to the total effect of temperature change on the uptake rate is expected to be negligible within the small range of temperature variations usually encountered during a single environmental sampling event, especially in soil-gas sampling which is the most widely used application of the WMS.
Related Concept Videos
Subatomic Particles
Molar Mass
Passive Filters
Low-Pass Filters
Low-pass filters are designed to transmit signals with frequencies lower than the cutoff frequency, ωc, and attenuate those above it. The cutoff...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Active versus Passive Immunity
Active Immunity
Active immunity refers to the resistance one develops...
Sample Preparation for Analysis: Overview
Bulk or large solid samples are typically reduced in size using grinding, crushing, or milling techniques to increase the...

