Related Experiment Video
Updated: Jan 29, 2026

Non-restraining EEG Radiotelemetry: Epidural and Deep Intracerebral Stereotaxic EEG Electrode Placement
Published on: June 25, 2016
Epidural electrical stimulation test versus local anesthetic test dose for thoracic epidural catheter placement: a
Mrinalini Balki1,2,3, Archana Malavade4, Xiang Y Ye5
1Department of Anesthesia and Pain Management, Mount Sinai Hospital, University of Toronto, 600 University Avenue, Toronto, ON, M5G 1X5, Canada. Mrinalini.balki@uhn.ca.
Purpose:
This study examined the concordance between epidural electrical stimulation test (EEST) and local anesthetic (LA) test dose to indicate correct thoracic epidural catheter position. The relationship between the test results and epidural postoperative analgesia was also assessed.
Methods:
This prospective observational cohort study was done in patients receiving thoracic epidural analgesia for abdominal surgery. After insertion, the epidural catheter was tested using a nerve stimulator to elicit a motor response. The LA test dose was then administered, and sensory block to ice and pinprick was assessed. The primary outcome was the presence/absence of motor response to EEST and sensory block to test dose. Concordance of responses was assessed using kappa statistics, and their predictive power of postoperative epidural analgesia was evaluated.
Results:
Sixty-eight thoracic epidural catheters were inserted, of which 62 were used perioperatively. The kappa agreement between EEST and LA test dose responses was moderate at 0.42 (95% confidence interval [CI], 0.18 to 0.67). Positive responses to EEST and LA test dose were observed in 62 (100%) and 50 (81%) patients, respectively, while 52 patients (84%) showed adequate analgesia postoperatively. The sensitivity (95% CI) of EEST and LA test dose to predict adequate postoperative epidural analgesia was 1 (0.93 to 1) and 0.79 (0.65 to 0.89), respectively, and the positive predictive values (95% CI) of EEST and LA test dose were 0.84 (0.75 to 0.93) and 0.82 (0.71 to 0.92), respectively.
Conclusion:
Following thoracic epidural catheter insertion, the responses to the EEST and LA test dose showed "moderate" agreement. The EEST has a higher sensitivity than the LA test dose to predict adequate epidural analgesia following abdominal surgery, however, both tests have a comparable positive predictive value.
Related Concept Videos
Local Anesthetics: Clinical Application as Epidural Anesthesia
Since epidural anesthetics can be infused through an epidural catheter, all types of drugs, including short-acting ones, can be administered. Chloroprocaine and lidocaine are examples of short and long-duration anesthetics, respectively. Bupivacaine...
Local Anesthetics: Pharmacokinetics
Local Anesthetics: Mechanism of Action
Local anesthetics are amphiphilic molecules consisting of a hydrophobic aromatic part linked to a hydrophilic group by an ester or amide linkage. They are weak bases and are usually available as salts, which increases their solubility and stability. Once administered, LAs exist in the body either...
Local Anesthetics: Adverse Effects
Once absorbed into the systemic circulation, local anesthetics can affect the organs that depend on the functioning of sodium...
Local Anesthetics: Common Agents and Their Applications
Cocaine is an ester of benzoic acid and methylecgogine. It is used to anesthetize and vasoconstrict locally. Currently, it is used primarily for topical applications. It is beneficial for surgeries on the upper respiratory tract, providing anesthesia and shrinking the mucosa. Cocaine in the form of cocaine hydrochloride is...
Observational Studies
There are three types of observational studies – Prospective, retrospective, and cross-sectional.
Prospective Study
Prospective studies, also known as longitudinal or cohort studies, are carried out by collecting future data from groups sharing similar characteristics. One...

