Related Experiment Video
Updated: Jan 29, 2026

Electrochemiluminescence Assays for Human Islet Autoantibodies
Published on: March 23, 2018
Combining immunofluorescence with immunoblot assay improves the specificity of autoantibody testing for myositis
M Infantino1, M Tampoia2, M Fabris3
1Laboratorio Immunologia e Allergologia, Ospedale S. Giovanni di Dio, Firenze, Azienda USL Toscana Centro, Italy.
Objective:
Immunoblot (IB) methods are widely used to detect myositis-specific autoantibodies (MSAs); however, false-positive results are common. In this study, we aimed to determine whether associating the anti-nuclear antibody (ANA) IIF pattern may help to improve the specificity of MSA detection by IB in patients with idiopathic inflammatory myositis (IIM).
Methods:
Serum samples from 104 patients presenting with muscle weakness/myalgia and positive to at least one MSA by IB (MYOS12 Diver and MIOS7 Diver, D-tek) were tested for ANAs on HEp-2000 cells (Immuno Concepts). The chi-square test was used to analyse the concordance of the MSA result and its corresponding pattern by ANA testing between patients with and without IIM.
Results:
Eighty-three of the 104 patients had a diagnosis of definite IIM, while in 21 cases, patients were affected by other autoimmune diseases or various non-systemic diseases. Forty nine of 83 (59%) patients in the IIM group and 4/21 (19%) in the non-IIM group showed a concordance between ANA pattern and MSAs by IB (P < 0.001). MSA monopositivity was significantly associated with IIM (91.6%) compared with 61.9% in the non-IIM group (P = 0.0005).
Conclusions:
Considering both the MSA result and its corresponding pattern by ANA testing may help to improve the specificity of MSA detection by IB and to confirm the diagnosis of MSA-associated IIM. The monopositivity of MSAs is an important additional tool to validate IB results.
More Related Videos
07:20A Simple Cell-based Immunofluorescence Assay to Detect Autoantibody Against the N-Methyl-D-Aspartate NMDA Receptor in Blood
Published on: January 9, 2018
09:58Quantitative Immunoblotting of Cell Lines as a Standard to Validate Immunofluorescence for Quantifying Biomarker Proteins in Routine Tissue Samples
Published on: January 7, 2019
Related Concept Videos
Improving Translational Accuracy
Improving Translational Accuracy
Immunofluorescence Microscopy
Specific Heat
For example, increasing the temperature of one gram of water by 1°C requires one calorie of heat energy and can be written as 1 cal/g-°C, or...
Impedance Combination
Testes: Histology
The spermatogenic cells, responsible for producing sperm, are...