Related Experiment Video
Updated: Jan 29, 2026

High-throughput Siderophore Screening from Environmental Samples: Plant Tissues, Bulk Soils, and Rhizosphere Soils
Published on: February 9, 2019
Determination of radon exhalation rates in soil samples using sealed can technique and CR-39 detectors
1Faculty of Science and Technology, Hebron University, PO Box 40, Hebron, Palestine.
Background:
In this study, the so-called sealed can technique dosimeters have been used to determine the radon exhalation rates in soil samples collected from different sites in Bethlehem region- Palestine.
Methods:
For the measurement of radon concentration emanated from these samples, alpha-sensitive, Solid State Nuclear Track Detectors (SSNTD's) have been used. A total of 82 soil samples were collected simultaneously.
Results:
It was found that the radon concentrations in these soil samples varied from 19.1 Bqm-3 to 572.9 Bqm-3 with an average value of 145.0 Bqm-3. The radon exhalation rate in these collected samples also varied from 6.9 mBqm-2 h-1 (0.26 mBqkg-1 h-1) to 207.2 mBqm-2 h-1 (7.84 mBqkg-1 h-1) with an a total average value of 52.2 mBqm-2 h-1 (1.97 mBqkg-1 h-1).
Conclusions:
All the values of radium content in all samples under test were found to be quite lower than the corresponding the global value 30 Bqkg-1. The present results show that the radon concentration and the resulting doses in all soil samples are below the allowed limit from ICRP. The radiological health implication to the population that may result from these doses is found to be low. The measurements have been taken as representing a baseline database of values of these radionuclides in the soils in the area. The results were compared with national and worldwide results.
Related Concept Videos
Rate-Determining Steps
In a multistep reaction mechanism, one of the elementary steps progresses significantly slower than the others. This slowest step is called the rate-limiting step (or rate-determining step). A reaction cannot proceed faster than its slowest step, and hence, the rate-determining step limits the overall reaction rate.
The concept of rate-determining step can be understood from the analogy of a 4-lane freeway with a short-stretch of traffic-bottleneck caused due to...
The Soil Ecosystem
Pulmonary Cycle: Exhalation
Determination of Michaelis Constant and Maximum Elimination Rate
These parameters can be estimated by analyzing plasma concentration data post-drug administration. A notable example of this application is phenytoin, a drug with capacity-limited kinetics. It's recommended that phenytoin should be administered at two...
Measuring Reaction Rates
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...

