Related Experiment Video
Updated: Jan 29, 2026

Constructing and Visualizing Models using Mime-based Machine-learning Framework
Published on: July 22, 2025
Bundled Care for Hip Fractures: A Machine-Learning Approach to an Untenable Patient-Specific Payment Model
Jaret M Karnuta1, Sergio M Navarro2, Heather S Haeberle3
1Department of Orthopedic Surgery, Cleveland Clinic, Cleveland, OH.
Objectives:
With the transition to a value-based model of care delivery, bundled payment models have been implemented with demonstrated success in elective lower extremity joint arthroplasty. Yet, hip fracture outcomes are dependent on patient-level factors that may not be optimized preoperatively due to acuity of care. The objectives of this study are to (1) develop a supervised naive Bayes machine-learning algorithm using preoperative patient data to predict length of stay and cost after hip fracture and (2) propose a patient-specific payment model to project reimbursements based on patient comorbidities.
Methods:
Using the New York Statewide Planning and Research Cooperative System database, we studied 98,562 Medicare patients who underwent operative management for hip fracture from 2009 to 2016. A naive Bayes machine-learning model was built using age, sex, ethnicity, race, type of admission, risk of mortality, and severity of illness as predictive inputs.
Results:
Accuracy was demonstrated at 76.5% and 79.0% for length of stay and cost, respectively. Performance was 88% for length of stay and 89% for cost. Model error analysis showed increasing model error with increasing risk of mortality, which thus increased the risk-adjusted payment for each risk of mortality.
Conclusions:
Our naive Bayes machine-learning algorithm provided excellent accuracy and responsiveness in the prediction of length of stay and cost of an episode of care for hip fracture using preoperative variables. This model demonstrates that the cost of delivery of hip fracture care is dependent on largely nonmodifiable patient-specific factors, likely making bundled care an implausible payment model for hip fractures.
Related Concept Videos
Patient-centered Care
Simplified Synchronous Machine Model
In this model, each generator is connected to a...
Wind Turbine Machine Models
Induction machines interact through the rotating magnetic field generated by the stator and the rotor. The key parameter is slip, which is the difference between synchronous speed and rotor speed relative to synchronous speed. Slip is...
Machines
A free-body diagram of the...
Machines: Problem Solving II
Machines: Problem Solving I
The toggle clamp system is a machine structure consisting of movable, pin-connected multi-force members that form a stabilized system to transmit forces. The...

