Background:
There is controversy about optimal limb alignment following knee replacement. An aim of using Oxford medial unicompartmental knee replacement (UKR) implants is to accurately restore normal ligament tension in the knee, thereby restoring normal kinematics. This return to normal tension typically results in a return to prearthritic alignment, which is frequently varus. The aim of this study was to investigate the relationship between postoperative limb alignment and postoperative patient-reported outcome and implant revision rate.
Methods:
We used a consecutive cohort of 891 knees with cemented Oxford medial UKR implants with a mean 10-year follow-up and recorded alignment. We grouped knees according to postoperative mechanical alignment as marked varus (estimated at 10°), mild varus (estimated at 5°), neutral, and valgus. The mean Oxford Knee Score (OKS) was calculated at 5 and 10 years postoperatively. Revision risk was assessed by survival analysis and component-time incidence rates.
Results:
Postoperatively, 67 (8%) of the 891 knees were in marked varus; 308 (35%), in mild varus; 508 (57%), in neutral; and 8 (1%), in valgus. The valgus group (8 knees) was too small for further analysis. The mean OKS (and standard deviation [SD]) at 10 years postoperatively was 41.7 ± 7 for marked varus, 40.5 ± 8 for mild varus, and 39.4 ± 9 for neutral alignment (p = 0.28). At 10 years, 92%, 85%, and 76% achieved a good or excellent OKS outcome, respectively (p = 0.02). Twelve-year survival rates were 93.3% for marked varus, 93.2% for mild varus, and 93.6% for neutral alignment, respectively (p = 0.53). Revision incidence rates per 100 component-years were 0.49 (95% confidence interval [CI], 0.2 to 1.5), 0.36 (95% CI, 0.2 to 0.7), and 0.54 (95% CI, 0.4 to 0.8), respectively, and were not significantly different (p = 0.53).
Conclusions:
Marked postoperative varus mechanical alignment of an estimated 10° was present in 8%, and mild varus of about 5° was present in 35%. Increasing varus alignment was associated with an increasing percentage of good or excellent OKS outcomes, but otherwise there were no significant differences between alignment groups in patient-reported outcome or revision rate. These data support the standard operative technique for the Oxford UKR, which aims to restore ligament tension and therefore prearthritic alignment rather than neutral mechanical alignment.
Level Of Evidence:
Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Related Concept Videos
Introduction to Test of Independence
The test statistic for a test of independence is similar to that of a goodness-of-fit test:
Hypothesis Test for Test of Independence
H0: The two variables (factors)...
Knee Joint
A total of seven ligaments support the knee joint. The patellar ligament, which is also attached to the quadriceps femoris...
Law of Independent Assortment
Reaction Rate
The mathematical representation of the change in the concentration of reactants and products, over time, is the rate...
Concentration and Rate Law
For example, in a generic reaction aA + bB ⟶ products, where a and b are stoichiometric coefficients, the rate law can be written as: