Detailed modeling and advanced control for chemical disinfection of secondary effluent wastewater by peracetic acid
Kyriakos Manoli1, Siva Sarathy1, Roberta Maffettone1
1Trojan Technologies, London, ON, N5V4T7, Canada; Department of Chemical and Biochemical Engineering, University of Western Ontario, London, ON, N6A5B9, Canada.
Abstract:
Advanced control of chemical disinfection processes is becoming increasingly important in view of balancing under-treatment (low pathogen inactivation) and over-treatment (excessive consumption of disinfectant and disinfection byproducts formation) thereby providing considerable environmental and economic benefits. Conventional control strategies such as flow pacing or residual trim ignore chemical demand/decay, inactivation kinetics, and other factors governing disinfection performance in continuous-flow reactors such as reactor hydraulics and process variability. This study presents the development, verification, and pilot-scale validation of a novel CT-based real-time disinfection control strategy, derived from first principles, and applied to peracetic acid disinfection of municipal secondary effluent wastewater. Validation experiments were carried out using a 3-m3 pilot contact basin of which the hydraulic performance was first characterized by means of tracer tests and then mathematically modeled using the well-established theoretical framework of continuous stirred-tank reactors in series. The analytical model describing hydraulic performance was subsequently extended to take into account disinfectant demand/decay and microbial inactivation kinetics. The integrated model was successfully used to predict, and control, residual peracetic acid as well as microbial concentration in the pilot effluent. Validation studies conclusively supported that the novel CT-based control strategy was superior in maintaining constant disinfection performance, desired microbial counts, and low residual disinfectant under variable flow and wastewater quality. When compared with flow pacing, the CT-based control required two times less the amount of chemical for the same treatment objective (<100 cfu/100 mL). Remarkably, the CT-based control strategy could be extended to other chemical disinfection processes such as chlorination and ozonation, alone or in combination with physical treatment technologies such as membranes and ultraviolet irradiation.
More Related Videos
Related Concept Videos
Chemical Agents for Microbial Control
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Secondary Active Transport
Nucleic Acids
DNA and RNA
The two main types of nucleic acids are deoxyribonucleic acid (DNA) and ribonucleic acid (RNA). DNA is the genetic material in all living organisms, ranging from single-celled bacteria to multicellular mammals. It is in the nucleus of eukaryotes and in the organelles, chloroplasts, and mitochondria. In prokaryotes,...
Chemical Formulas
Secondary Healthcare System