Metallic artifact reduction by evaluation of the additional value of iterative reconstruction algorithms in hip
Angeliki Neroladaki1, Steve Philippe Martin, Ilias Bagetakos
1Radiology Department, Geneva University Hospital, Genève, Switzerland.
Abstract:
To evaluate iterative metal artifact reduction (iMAR) technique in images data of hip prosthesis on computed tomography (CT) and the added value of advanced modeled iterative reconstruction (ADMIRE) compared with standard filtered back projection (FBP).Twenty-eight patients addressed to CT examinations for hip prosthesis were included prospectively. Images were reconstructed with iMAR algorithm in addition to FBP and ADMIRE techniques. Measuring image noise assessed objective image quality and attenuation values with standardized region of interest (ROI) in 4 predefined anatomical structures (gluteus medius and rectus femoris muscles, inferior and anterior abdominal fat, and femoral vessels when contrast media was present). Subjective image quality was graded on a 5-point Likert scale, taking into account the size of artifacts, the metal-bone interface and the conspicuity of pelvic organs, and the diagnostic confidence.Improvement in overall image quality was statistically significant using iMAR (P<.001) compared with ADMIRE and FBP. ADMIRE did not show any impact in image noise, attenuation value, or global quality image. iMAR showed a significant decrease in image noise in all ROIs (Hounsfield Unit) as compared with FBP and ADMIRE. Interobserver agreement was high in all reconstructions (FBP, FBP+iMAR, ADMIRE, and ADMIRE + iMAR) more than 0.8. iMAR reconstructions showed emergence of new artifacts in bone-metal interface.iMAR algorithm allows a significant reduction of metal artifacts on CT images with unilateral or bilateral prostheses without additional value of ADMIRE. It improves the analysis of surrounding tissue but potentially generates new artifacts in bone-metal interface.
More Related Videos
08:19Protocol for the Evaluation of MRI Artifacts Caused by Metal Implants to Assess the Suitability of Implants and the Vulnerability of Pulse Sequences
Published on: May 17, 2018
07:58Computational Reconstruction of Pancreatic Islets as a Tool for Structural and Functional Analysis
Published on: March 9, 2022
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Oxidation-Reduction Reactions
Metal-Ligand Bonds
In these complexes, transition metals form coordinate covalent bonds, a kind of Lewis acid-base interaction in which both of the electrons in the bond are contributed by a donor (Lewis base) to an electron acceptor (Lewis acid). The Lewis acid in...
Conjugate Addition (1,4-Addition) vs Direct Addition (1,2-Addition)
Conjugate addition results in a thermodynamically stable product. The reaction retains the stronger C=O bond at the expense of the weaker C=C π bond. The process is slow as the β carbon is less electrophilic than the carbonyl carbon.
Direct addition products are...