Monitoring Lung Function with Electrical Impedance Tomography in the Intensive Care Unit
Published on: September 6, 2024
Monitoring changes in distribution of pulmonary ventilation by functional electrical impedance tomography in
Ulrike Auer1, J Peter Schramel1, Yves P Moens1
1Division of Anaesthesiology and Perioperative Intensive Care, University of Veterinary Medicine Vienna, Vienna, Austria.
Objective:
To assess changes in the distribution in pulmonary ventilation in anaesthetized ponies using electrical impedance tomography (EIT).
Study Design:
Prospective experimental study.
Animals:
A group of eight adult pony geldings.
Methods:
General anaesthesia was induced and maintained using isoflurane in oxygen with volume-controlled ventilation [tidal volume (VT) (10 mL kg-1), respiratory rate (8-12 breaths minute-1)] to maintain end-tidal carbon dioxide between 35 and 40 mmHg (4.66-5.32 kPa). Regional distribution of ventilation was assessed with EIT (plane of fifth to sixth intercostal space) at 30, 60 and 90 minutes after intubation. The resulting functional images were divided into four regions of interest (ROI, A-D) to determine: 1) the ratio of VT distribution between dependent to nondependent lung (D/ND) and 2) changes in distribution within the lungs in the latero-lateral direction. The centre of ventilation (COV) was calculated. The dimension of the chest in the latero-lateral (W) and dorso-ventral (H) direction was measured at the height of the withers and the W/H ratio was calculated. The influence of time on the D/ND ratio, COV and ROI A-D were analysed with anova followed by post hoc Bonferroni tests. Pearson correlation coefficient and the coefficient of determination (r2) were calculated to evaluate the relationship between the W/H ratio and D/ND ratio, and COV. Statistical significance was set at p < 0.05.
Results:
The median D/ND ratio (T30-T90) was 0.67 (0.40-1.01) and for COV 31.15% (11.20-45.20), confirming the expected uneven distribution of ventilation. The D/ND ratio had a moderate negative correlation with the W/H ratio (r = -0.68, r2 = 0.46, p < 0.001), while the COV did not correlate with the W/H ratio (r = -0.04).
Conclusions And Clinical Relevance:
Uneven ventilation in mechanically ventilated right laterally recumbent anaesthetized ponies occurs within 30 minutes and changed little over the following 60 minutes.
More Related Videos
05:56Author Spotlight: Enhancing Diagnostic Strategies and Biomarker Development for Comprehensive Lung Function Analysis
Published on: August 9, 2024
08:06Author Spotlight: Optimizing Porous Substrate Electroporation Through Micro and Nanochannels for Enhanced Monitoring and Intermediate Stage Characterization
Published on: September 27, 2024
Related Concept Videos
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Pulmonary Ventilation: Inhalation
Boyle's law becomes particularly pertinent when examining respiratory...
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...