Gas chromatography-Mass Spectra analysis and deleterious potential of fungal based polythene-degradation products

Manisha K Sangale1,2, Mohd Shahnawaz3,4, Avinash B Ade5

  • 1Department of Botany, Savitribai Phule Pune University, Pune, 411007, Maharashtra, India.

Scientific Reports
|February 9, 2019
PubMed

Insights

This study analyzed polythene-degradation products (PE-DPs) from Aspergillus fungi. PE-DPs showed no negative impact on sorghum seed germination but slightly inhibited seedling elongation, with no harm to tiger sharks.

Area of Science:

  • Environmental microbiology
  • Bioremediation of plastics
  • Fungal degradation of polymers

Background:

  • Polythene, a persistent pollutant, requires effective degradation strategies.
  • Fungal isolates Aspergillus terreus and Aspergillus sydowii show promise in breaking down polythene.
  • Understanding the byproducts of polythene degradation is crucial for assessing environmental safety.

Purpose of the Study:

  • To analyze polythene-degradation products (PE-DPs) generated by efficient fungal isolates.
  • To evaluate the ecotoxicity of PE-DPs on plant (Sorghum) and animal (Tiger shark) systems.
  • To determine the safety of using these fungi for polythene bioremediation.

Main Methods:

  • Fungal isolates (Aspergillus terreus, Aspergillus sydowii) incubated with polythene for 60 days.
  • Polythene-degradation products analyzed using Gas Chromatography-Mass Spectrometry (GC-MS).
  • Ecotoxicity assessed via sorghum seed germination and elongation tests, and tiger shark mortality tests.

Main Results:

  • 24 polythene-degradation products identified in treated samples.
  • Sorghum seed germination rate unaffected; germination index maximized at 50% PE-DP concentration.
  • Highest elongation inhibition rate (34.75%) observed with Aspergillus terreus PE-DPs; no tiger shark mortality recorded.

Conclusions:

  • The analyzed PE-DPs from Aspergillus terreus and Aspergillus sydowii exhibit low ecotoxicity.
  • These fungal isolates are potential candidates for polythene bioremediation with minimal environmental risk.
  • Further research into specific PE-DPs and their long-term effects is warranted.

Related Concept Videos

Gas Chromatography–Mass Spectrometry (GC–MS)01:14

Gas Chromatography–Mass Spectrometry (GC–MS)

Gas chromatography–mass spectrometry (GC–MS) is the combination of analytical techniques of gas chromatography and mass spectrometry in a single instrument for analyzing a mixture of compounds. The gas chromatograph separates the compounds in the mixture, and the mass spectrometer analyzes each compound separately to determine the molecular masses and molecular structures.
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
6.7K
Gas Chromatography: Introduction01:13

Gas Chromatography: Introduction

Gas chromatography (GC) is a technique for separating and analyzing volatile compounds in a sample. Its primary purpose is to identify and quantify components in complex mixtures, making it essential in fields such as environmental analysis, pharmaceuticals, and petrochemicals. GC is also called vapor-phase chromatography (VPC) or gas-liquid partition chromatography (GLPC).
In GC,  a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
3.9K
Gas Chromatography: Overview of Detectors01:13

Gas Chromatography: Overview of Detectors

Detectors in gas chromatography (GC) help identify and quantify the components of a mixture by translating chemical properties into measurable signals, which are displayed on a chromatogram. Detectors can be categorized into two main types: destructive and non-destructive.
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
2.0K
Gas Chromatography: Types of Detectors-II01:19

Gas Chromatography: Types of Detectors-II

In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...
1.2K
Gas Chromatography: Types of Detectors-I01:21

Gas Chromatography: Types of Detectors-I

There are different types of detectors used in gas chromatography, each with its own specific properties that make it suitable for detecting certain types of analytes. The most commonly used detectors in GC are thermal conductivity detector (TCD), flame ionization detector (FID), and electron capture detector (ECD).
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
1.6K
Applications of the Ideal Gas Law: Molar Mass, Density, and Volume03:43

Applications of the Ideal Gas Law: Molar Mass, Density, and Volume

The volume occupied by one mole of a substance is its molar volume. The ideal gas law, PV = nRT,  suggests that the volume of a given quantity of gas and the number of moles in a given volume of gas vary with changes in pressure and temperature. At standard temperature and pressure, or STP (273.15 K and 1 atm), one mole of an ideal gas (regardless of its identity) has a volume of about 22.4 L — this is referred to as the standard molar volume.
63.3K