Related Experiment Video
Updated: Jan 29, 2026

Design of a Biaxial Mechanical Loading Bioreactor for Tissue Engineering
Published on: April 25, 2013
Limitations imposed by conventional fine bubble diffusers on the design of a high-loaded membrane bioreactor (HL-MBR)
Sang Yeob Kim1,2, Hector A Garcia3, Carlos M Lopez-Vazquez1
1Department of Environmental Engineering and Water Technology, IHE Delft Institute for Water Education, Westvest 7, 2611AX, Delft, The Netherlands.
Abstract:
The operation of membrane bioreactors (MBRs) at higher than usual mixed liquor suspended solids (MLSS) concentrations may enhance the loading rate treatment capacity while minimizing even further the system's footprint. This requires operating the MBR at the highest possible MLSS concentration and biomass activity (e.g., at high loading rates and low solid retention times (SRTs)). Both a negative effect of the MLSS concentrations and a positive effect of the SRT on the oxygen transfer have been reported when using conventional fine bubble diffusers. However, most of the evaluations have been carried out either at extremely high SRTs or at low MLSS concentrations eventually underestimating the effects of the MLSS concentration on the oxygen transfer. This research evaluated the current limitations imposed by fine bubble diffusers in the context of the high-loaded MBR (HL-MBR) (i.e., high MLSS and short SRT-the latter emulated by concentrating municipal sludge from a wastewater treatment plant (WWTP) operated at a short SRT of approximately 5 days). The high MLSS concentrations and the short SRT of the original municipal sludge induced a large fraction of mixed liquor volatile suspended solids (MLVSS) in the sludge, promoting a large amount of sludge flocs that eventually accumulated on the surface of the bubbles and reduced the free water content of the suspension. Moreover, the short SRTs at which the original municipal sludge was obtained eventually appear to have promoted the accumulation of surfactants in the sludge mixture. This combination exhibited a detrimental effect on the oxygen transfer. Fine bubble diffusers limit the maximum MLSS concentration for a HL-MBR at 30 g L-1; beyond that point is either not technically or not economically feasible to operate; an optimum MLSS concentration of 20 g L-1 is suggested to maximize the treatment capacity while minimizing the system's footprint.
Related Concept Videos
Protein Diffusion in the Membrane
Physiological Pharmacokinetic Models: Blood Flow-Limited Versus Diffusion-Limited Models
Design of Columns under a Centric Load
Euler's formula is applicable under the assumption that the column is a perfect, straight, homogenous prism, and it is operating...
Design of Columns under an Eccentric Load
Diffusion
Excess Pressure Inside a Drop and a Bubble

