Limitations imposed by conventional fine bubble diffusers on the design of a high-loaded membrane bioreactor (HL-MBR)

Sang Yeob Kim1,2, Hector A Garcia3, Carlos M Lopez-Vazquez1

  • 1Department of Environmental Engineering and Water Technology, IHE Delft Institute for Water Education, Westvest 7, 2611AX, Delft, The Netherlands.

Related Concept Videos

Protein Diffusion in the Membrane01:24

Protein Diffusion in the Membrane

Proteins show rotational as well as lateral diffusion across the membrane. The lateral diffusion of proteins was confirmed through the cell fusion experiment where mouse and human cells were fused, resulting in hybrid cells. When the human and mouse cells fused, the specific membrane proteins on human and mouse cells were marked with the red and green-fluorescent markers, respectively. Initially, the red and green fluorescence was located on the respective hemisphere of the cell. As time...
5.6K
Physiological Pharmacokinetic Models: Blood Flow-Limited Versus Diffusion-Limited Models00:57

Physiological Pharmacokinetic Models: Blood Flow-Limited Versus Diffusion-Limited Models

Physiological pharmacokinetic models, often called flow-limited or perfusion models, typically assume a swift drug distribution between tissue and venous blood, creating a rapid drug equilibrium. This premise is based on the idea that drug diffusion is extremely fast, and the cell membrane presents no barrier to drug permeation. In this scenario, where no drug binding occurs, the drug concentration in the tissue equals that of the venous blood leaving the tissue. This greatly simplifies the...
349
Design of Columns under a Centric Load01:17

Design of Columns under a Centric Load

The design of columns under centric load is a fundamental aspect of structural engineering and is critical for ensuring the stability and integrity of structures. Euler's and Secant's formulas are central to understanding and calculating the critical load and deformation behaviors of columns, providing a basis for safe and effective structural design.
Euler's formula is applicable under the assumption that the column is a perfect, straight, homogenous prism, and it is operating...
552
Design of Columns under an Eccentric Load01:21

Design of Columns under an Eccentric Load

Designing columns to withstand eccentric loads is a critical aspect of structural engineering, ensuring structures can support off-center loads without failure. This design process must account for the additional normal stresses introduced by eccentric loading, which can significantly influence a column's stress distribution and overall stability. An eccentric load applied to a column induces normal stresses that can be conceptualized as a combination of stresses due to an equivalent...
1.2K
Diffusion01:12

Diffusion

Diffusion is the passive movement of substances down their concentration gradients—requiring no expenditure of cellular energy. Substances, such as molecules or ions, diffuse from an area of high concentration to an area of low concentration in the cytosol or across membranes. Eventually, the concentration will even out, with the substance moving randomly but causing no net change in concentration. Such a state is called dynamic equilibrium, which is essential for maintaining overall...
218.0K
Excess Pressure Inside a Drop and a Bubble01:13

Excess Pressure Inside a Drop and a Bubble

The shape of a small drop of liquid can be considered spherical, neglecting the effect of gravity. This drop can further be considered as two equal hemispherical drops put together due to surface tension. The forces acting on the spherical drop are due to the pressure of the liquid inside the drop, the pressure due to air outside the drop, and the force due to the surface tension acting on the two hemispherical drops.
3.4K