Related Experiment Video
Updated: Jan 29, 2026

Injection of Porcine Adipose Tissue-Derived Stroma Cells via Waterjet Technology
Published on: November 23, 2021
Permeability of the porcine iris stroma
Royston K Y Tan1, Xiaofei Wang2, Anita S Y Chan3
1Ophthalmic Engineering & Innovation Laboratory, Department of Biomedical Engineering, Faculty of Engineering, National University of Singapore, Singapore.
Abstract:
Current literature has not considered or provided any data on the permeability of the iris stroma. In this study, we aimed to determine the hydraulic permeability of porcine irides from the isolated stroma. Fifteen enucleated porcine eyes were acquired from the local abattoir. The iris pigment epithelium was scraped off using a pair of forceps and the dilator muscles were pinched off using a pair of colibri toothed forceps. We designed an experimental setup, based on Darcy's law, and consisting of a custom 3D-printed pressure column using acrylonitrile butadiene styrene (ABS) plastic. PBS solution was passed through the iris stroma in a 180° arc shape, with a column height of approximately 204 mm (2000 Pa). Measurements of iris stromal thickness were conducted using optical coherence tomography (OCT). To measure flow rate, we measured the mass (volume) of PBS solution using a mass balance in approximately 1 min. Histology was performed using hematoxylin and eosin (H&E) and anti-smooth muscle antibody (anti-α-SMA) for validation. The permeability experiments demonstrated that the iris stroma is a biphasic tissue that allows fluid flow. Our image processing results determined the area of flow to be 7.55 mm2 and the tissue thickness to be between 180 and 430 μm. The hydraulic permeability of the porcine stroma, calculated using Darcy's law, was 5.13 ± 2.39 × 10-5 mm2/Pa•s. Histological and immunochemical studies confirmed that the tissues used for this permeability study were solely iris stroma. Additionally, anti-α-SMA staining revealed staining specific for stromal blood vessels, with the notable absence of dilator and sphincter muscle staining. Our study combined experimental microscopic data with the theory of biphasic materials to investigate the hydraulic permeability of the iris stroma. This work will serve as a basis on which to validate future biomechanical studies of human irides with which may ultimately aid disease diagnosis and inform the design of novel treatments.
Related Concept Videos
Protein Transport to the Stroma
Protein complexes called the translocon of the outer chloroplast membrane or TOC complex, and the translocon of the inner chloroplast membrane or TIC complex mediate the...
Permeability of Concrete
Magnetic Susceptibility and Permeability
When diamagnetic materials are placed under an external magnetic field, the moments opposite to the field are induced. Hence, the susceptibility for diamagnets has a minimal negative value of 10-5–10-6. Since...
Factors Affecting Drug Distribution: Tissue Permeability
Small molecules with a molecular weight below 500 to 600 Daltons can easily pass through the capillary membrane, gaining access to different tissues. Larger...
Bioavailability Enhancement: Drug Permeability Enhancement
Factors Affecting Dissolution: Drug Permeability, Stability and Stereochemistry

