Impact of spot size variations on dose in scanned proton beam therapy
Background:
In scanned proton beam therapy systematic deviations in spot size at iso-center can occur as a result of changes in the beam-line optics. There is currently no general guideline of the spot size accuracy required clinically. In this work we quantify treatment plan robustness to systematic spot size variations as a function of spot size and spot spacing, and we suggest guidelines for tolerance levels for spot size variations.
Methods:
Through perturbation of spot size in treatment plans for 7 patients and a phantom, we evaluated the dose impact of systematic spot size variations of 5% up to 50%. We investigated the dependence on nominal spot size by studying scenarios with small, medium and large spot sizes for various inter-spot spacings. To come to tolerance levels, we used the Γ passing rate and dose-volume-histograms.
Results:
Limits on spot size accuracy were extracted for 8 sites, 3 different spot sizes and 3 different inter-spot spacings. While the allowable spot size variation strongly depends on the spot size, the inter-spot spacing turned out to be only of limited influence.
Conclusions:
Plan robustness to spot size variations strongly depend on spot size, with small spot plans being much more robust than larger spots plans. Inter-spot spacing did not influence plan robustness. Combining our results with existing literature, we propose limits of ±25%, ±20% and ±10% of the spot width σ, for spots with σ of 2.5, 5.0 and 10 mm in proton therapy spot scanning facilities, respectively.
More Related Videos
05:56Spot Variation Fluorescence Correlation Spectroscopy for Analysis of Molecular Diffusion at the Plasma Membrane of Living Cells
Published on: November 12, 2020
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Dose Size and Dosing Frequency: Determination Methods
Impact Loading on a Cantilever Beam
When an object is dropped onto the free end of a cantilever, its potential energy due to gravity is...
What is Variation?
The range, standard deviation, standard error, and variance are the different measures of variation.
Range: The range is the difference between its maximum and...
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Variation
When independent and dependent variables are plotted on a scatter plot, the slope of a line is a value that describes the rate of change between the two...
Leaky Scanning