Stereotactic-Guided Dilatable Endoscopic Port Surgery for Deep-Seated Brain Tumors: Technical Report with Comparative

W Christopher Newman1, Johnathan A Engh2

  • 1Department of Neurological Surgery, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA.

World Neurosurgery
|February 11, 2019
PubMed
Abstract

Related Concept Videos

Comparing the Survival Analysis of Two or More Groups01:20

Comparing the Survival Analysis of Two or More Groups

Survival analysis is a cornerstone of medical research, used to evaluate the time until an event of interest occurs, such as death, disease recurrence, or recovery. Unlike standard statistical methods, survival analysis is particularly adept at handling censored data—instances where the event has not occurred for some participants by the end of the study or remains unobserved. To address these unique challenges, specialized techniques like the Kaplan-Meier estimator, log-rank test, and...
594
Cardiomyopathy II: Dilated Cardiomyopathy01:30

Cardiomyopathy II: Dilated Cardiomyopathy

Dilated cardiomyopathy, or DCM, is a progressive myocardial disorder characterized by ventricular chamber dilation and contractile dysfunction.EtiologyVarious factors can cause DCM, including hypertension and heavy alcohol intake, which contribute to the weakening and enlargement of the heart muscle. Viral infections, such as Coxsackievirus B, adenoviruses, and influenza, can lead to DCM by causing inflammation and damage to heart tissue. Certain chemotherapeutic agents, including daunorubicin,...
557
Resistors In Series01:10

Resistors In Series

A resistor is an ohmic device that limits the flow of charge in a circuit. Most circuits have more than one resistor. If several resistors are connected together and connected to a battery, the current supplied by the battery depends on the equivalent resistance of the circuit. The equivalent resistance of a combination of resistors depends on both their individual values and how they are connected. The simplest combination of resistors is the series combination. 
In a series circuit, the...
6.4K
Series Resonance01:17

Series Resonance

The RLC circuit impedance is defined as the ratio of the supply voltage to the circuit current. Resonance in such a circuit occurs when the imaginary part of this impedance equals zero. This specific condition means that the inductive reactance is exactly equal to the capacitive reactance. The frequency at which this happens is known as the resonant frequency. Mathematically, the resonant frequency is inversely proportional to the square root of the product of the inductance (L) and capacitance...
801
Data Reporting and Recording01:24

Data Reporting and Recording

Reporting and recording are crucial in data documentation. The timely, thorough, and accurate documentation of facts is essential when recording patient data. Failure to record findings during an assessment or interpretation of a problem will result in loss of information and make the patient document unreliable. The reader is left with general impressions if the information is not specific. A recording is documenting data of the individual's health information in a traceable, secure, and...
5.4K
Series and Parallel Capacitors01:14

Series and Parallel Capacitors

Capacitors, fundamental components in electronic circuits, can be connected in series and/or parallel configurations. Each configuration has different impacts on the overall behavior of the circuit.
First, consider capacitors connected in series to a battery. In this configuration, the plate connected to the battery's positive terminal develops a positive charge, while the plate attached to the negative terminal becomes negatively charged. An equal magnitude of charge is induced on the...
9.3K