Related Experiment Video
Updated: Jan 29, 2026

Use of Capillary Aerosol Generator in Continuous Production of Controlled Aerosol for Non-Clinical Studies
Published on: April 12, 2022
Design and Evaluation of an Aerodynamic Focusing Micro-Well Aerosol Collector
Jiayang He1, Igor V Novosselov1
1University of Washington, Mechanical Engineering, Box 352600, Seattle, WA 98195.
Abstract:
Aerosol sampling and identification is vital for the assessment and control of particulate matter pollution, airborne pathogens, allergens, and toxins and their effect on air quality, human health, and climate change. In-situ analysis of chemical and biological airborne components of aerosols on a conventional filter is challenging due to dilute samples in a large collection region. We present the design and evaluation of a micro-well (µ-well) aerosol collector for the assessment of airborne particulate matter (PM) in the 0.5-3 micron size range. The design minimizes particle collection areas allowing for in-situ optical analysis and provides an increased limit of detection for liquid-based assays due to the high concentrations of analytes in the elution/analysis volume. The design of the collector is guided by computational fluid dynamics (CFD) modeling; it combines an aerodynamic concentrator inlet that focuses the aspirated aerosol into a narrow beam and a µ-well collector that limits the particle collection area to the µ-well volume. The optimization of the collector geometry and the operational conditions result in high concentrations of collected PM in the submillimeter region inside the µ-well. Collection efficiency experiments are performed in the aerosol chamber using fluorescent polystyrene microspheres to determine the performance of the collector as a function of particle size and sampling flow rate. The collector has the maximum collection efficiency of about 75% for 1 micron particles for the flow rate of 1 slpm. Particles bigger than 1 micron have lower collection efficiencies because of particle bounce and particle loss in the aerodynamic focusing inlet. Collected samples can be eluted from the device using standard pipettes, with an elution volume of 10-20 microliters. The transparent collection substrate and the distinct collection region, independent of particle size, allows for in-situ optical analysis of the collected PM.
Related Concept Videos
Group Design
Factorial Design
Focusing of Light in the Eye
Coping Strategies: Problem Focused
For example, consider a student who struggles to understand their...
Design Example: Designing a Residential Plumbing System
Design Example: Designing Water Slide
Bernoulli's principle determines the water's velocity along the slide....