Related Experiment Video
Updated: Jan 29, 2026

Author Spotlight: Advancing Awake Nasotracheal Intubation with Flexible Video Rhino-Laryngoscopes
Published on: August 2, 2024
[Application of modified Weerda laryngoscopes in the ear, nose, and throat practice]
László Rovó1, Ádám Bach1, László Szakács1
1Fül-Orr-Gégészeti és Fej-Nyaksebészeti Klinika, Szegedi Tudományegyetem, Általános Orvostudományi Kar Szeged, Tisza Lajos krt. 111., 6725.
Abstract:
Microscope-assisted direct endoscopy of the airways and the upper gastrointestinal tract in general anesthesia is an essential diagnostic and therapeutic method of otorhinolaryngology. The quality of surgical exploration is a key for the good visibility and maneuverability of microsurgical tools. Beside the most commonly used Kleinsasser laryngoscope, the distending Weerda laryngoscope is a more favorable option for the exploration of the retrocricoid region. Narrow anatomical situation, examination and manipulation of lesions involving several sub-regions of the hypopharynx or larynx may be problematic in some cases even with this endoscope. The authors present the application of modified Weerda laryngoscopes with asymmetric spatula length in addition with four cases. The retrocricoid region, the distal part of the posterior hypopharyngeal wall and the proximal part of the esophagus can be easily visualized with this device. The modifications allow the introduction of new surgical techniques by increasing the number of applied microsurgical devices and their maneuverability. Orv Hetil. 2019; 160(7): 264-269.
Related Concept Videos
Nose and Nasal Cavity
Anatomy of the Ear
Characteristics of Practical Op Amps
The ratio of differential gain to the common-mode gain is defined as the common-mode rejection ratio (CMRR). This ratio quantifies the ability of operational amplifiers (op-amps) to reject common-mode...
Theoretical Foundations of Nursing Practice
Theories provide a perspective to assess patients' conditions and organize data and methods. They also assist in analyzing and interpreting information. They represent a...
Equivalent Circuits for Practical Transformers
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
Modified Boxplots
However, the box plot does not tell the reader about outliers - values that lie far from the center of the data. We can modify the standard box and whisker plot to identify the outliers and visualize the actual spread of the data in a sample.
Initially, we calculate the adjusted...