Cam-type femoroacetabular impingement-correlations between alpha angle versus volumetric measurements and surgical
Riham Dessouky1, Avneesh Chhabra2,3, Lihua Zhang2
1Department of Radiology, Zagazig University Hospitals and Faculty of Medicine, Zagazig University, Koliat Al Tob Street, Zagazig, 44519, Egypt.
Aim:
Determine correlations of 3DCT cam-type femoroacetabular impingement (FAI) measurements with surgical findings of labral tear and cartilage loss.
Methods:
Digital search of symptomatic cam-type FAI from July 2013 to August 2016 yielded 43 patients. Two readers calculated volumes of femoral head, bump, and alpha angles on 3DCT images. Correlations between CT and surgical findings, inter-, and intra-reader reliabilities were assessed using Spearman rank correlation and intraclass correlation coefficients (ICC).
Results:
Thirteen men and 14 women aged 37 ± 10 (mean ± SD) years were included. Most common clinical finding was positive flexion-adduction-internal rotation (70.4%). Twenty-seven labral tears and 20 cartilage defects were surgically detected. Significant correlations existed between femoral bump, head volumes, and extent of the labral tear (p = 0.008 and 0.003). No significant correlations were found between the alpha angles at 12 to 3 o'clock and the extent of labral tear (p = 0.2, 0.8, 0.9, and 0.09) or any measurement with the cartilage loss (p values for alpha 12 to 3, bump, and head volumes = 0.7, 0.3, 0.9, 0.9, 0.07, and 0.2). Inter- and intra-reader reliabilities were excellent to moderate for femoral head and bump volumes (ICC = 0.85, 0.52, and 0.8, 0.5) and moderate to poor for alpha angles (ICC = 0.48, 0.40, 0.05, 0.25 and 0.3, 0.24, 0.29, 0.49).
Conclusion:
Three dimensional volumetric measurements of cam-type FAI significantly correlate with the extent of intraoperative labral tears. Superior inter- and intra-reader reliability to that of alpha angles renders it a more clinically relevant measurement for quantifying cam morphology.
Key Points:
• The 3DCT bump volume and femoral head volume showed significant correlations with the extent of labral tear (p values = 0.008 and 0.003). • No significant correlations were seen between alpha angles and the extent of labral tear (p values > 0.05). • Inter- and intra-reader reliability was excellent to moderate (ICC = 0.85 and 0.52, 0.8, and 0.5) for femoral head and bump volumes while inter- and intra-reader reliability was fair to poor (ICC = 0.48, 0.40, 0.05, 0.25 and 0.3, 0.24, 0.29, 0.49) for alpha angles.
More Related Videos
08:19Author Spotlight: Unraveling the Mechanobiology of Tendon Impingement – A Multiaxial Murine Hind Limb Explant Model
Published on: December 8, 2023
08:25Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship
Published on: January 8, 2019
Related Concept Videos
C4 Pathway and CAM
C4 Pathway
The C4 pathway is used by plants such as...
Correlations
Correlation and Causation
Correlation versus Causation
If the dependent variable increases or decreases when the independent variable increases, there is a positive or negative...
Correlation
Two variables, for example, a and b, are said to be positively correlated if both variables move in the same direction. In other words, a positive correlation exists between two variables, a and b, if:
Contact Angle
The adhesive force is the molecular force between molecules of different materials, that is, between the molecules of the solid and the liquid. The cohesive...
Finding the Center of Gravity