Preparation of Peripheral Nerve Stimulation Electrodes for Chronic Implantation in Rats
Published on: July 14, 2020
Improvement of the Biocompatibility and Potential Stability of Chronically Implanted Electrodes Incorporating Coating
Bing Wang1, Pengbo Yang2, Yaxue Ding1
1Key Laboratory of Applied Surface and Colloid Chemistry, Ministry of Education, School of Chemistry and Chemical Engineering , Shaanxi Normal University , Xi'an 710062 , People's Republic of China.
Abstract:
The development of chronically implanted electrodes attracts much attention since these electrodes are much favorable for monitoring changes of neurotransmitters in brain science. The research in this field focused mainly on chemical modification to improve the potential stability and less on the biocompatibility. In this work, for the first time, we proposed the concept of cell-membrane electrodes based on a basic hypothesis using animal's self-cell membrane to reduce animal exclusiveness (hyperacute rejection and chronic rejection). As a proof of concept, we first studied cell-membrane reference electrodes for chronically implanted electrodes. Red cell membrane (RCM) was extracted from rat blood and coated on the chemically modified Ag/AgCl electrodes. It was found that ionic liquid (IL) 1-butyl-2,3-dimethylimidazolium hexafluorophosphate (BDMI) showed good performance rather than Nafion used as coating film for protection of silver chloride on Ag wire and support of the cell membrane. Electrochemical impedance spectra supported that charge-transfer resistance nearly kept constant before and after the electrodes were implanted into the rat's brain tissues for 28 days. Immunohistochemical analysis of the implant sites in the rat's brain tissues indicated that the extent of glial scarring arising from the Ag/AgCl/BDMI/RCM electrodes was smaller than that of both Ag/AgCl/Nafion and Ag/AgCl/Nafion/RCM electrodes after 28 days of implantation. The RCM-coated Ag/AgCl/IL electrodes showed a relatively potential stability compared to RCM-noncoated Ag/AgCl/IL electrodes after 28 days of implantation. Additionally, the current-voltage curve demonstrated that the RCM-coated electrodes can be used as polarized electrodes. This work demonstrated that the RCM, which was coated on the Ag/AgCl/IL electrodes, can significantly improve the biocompatibility and potential stability of the RCM-noncoated Ag/AgCl/IL electrodes implanted in the rat brain. The cell-membrane-coated electrodes will serve as a lighthouse in guiding the design of chronically implanted electrodes for in vivo electrochemical detection.
Related Concept Videos
Standard Electrode Potentials
The Resting Membrane Potential
Potentiometry: Membrane Electrodes
Resting Membrane Potential
The Inside of a Neuron is More Negative
The membrane potential of a cell can be measured by inserting a microelectrode into a cell and comparing the charge to a reference electrode in the extracellular fluid. The...
Cell Potential and Free Energy
Thermodynamics is the branch of physics dealing with the relationship between heat and other forms of energy. In an electrochemical cell, chemical energy is converted into electrical energy.
Thus, a link can be predicted between cell potential, free energy change, and the equilibrium constant for the reaction. Cell potential can also be measured as the oxidant or the reducing strength, and similar acid-base strength measures are reflected in equilibrium...
Nuclear Stability
To hold positively charged protons together...